HP StorageWorks 8/8 Brocade Access Gateway Administrator's Guide v6.3.0 (53-10 - Page 78
TABLE 10, connected to an M-EOS switch
View all HP StorageWorks 8/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
A Troubleshooting TABLE 10 Problem Troubleshooting (Continued) Cause Failover is not working Failover disabled on N_Port. Access Gateway is mode Access Gateway must be disabled. not wanted Solution Verify that the failover and failback policies are enabled, as follows: Enter the ag --failoverShow command with the port_number operand. Enter the ag --failbackShow command with the port_number operand. Command returns "Failback (or Failover) on N_Port port_number is supported." If it returns, "Failback (or Failover) on N_Port port_number is not supported." See "Adding a preferred secondary N_Port" on page 34. Disable switch using the switchDisable command. Disable Access Gateway mode using the ag --modeDisable command. Answer yes when prompted; the switch reboots. Log in to the switch. Display the switch settings using the switchShow command. Verify that the field switchMode displays Fabric OS Native mode. NOTE If a Fabric OS switch is in AG mode and is also set to McDATA Fabric mode, when that switch is connected to an M-EOS switch, the Fabric OS switch does not display in the output when you run the agshow command. 58 Access Gateway Administrator's Guide 53-1001345-01