HP StorageWorks MSA 2/8 HP StorageWorks Secure Fabric OS V1.0 User Guide (AA-R - Page 118
Zoning Commands, Table 21: Zoning Commands Executable on the Primary FCS Switch, command
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Secure Fabric OS Commands and Secure Mode Restrictions Table 20: Secure Fabric OS Commands Executable on Specific Switches When Secure Mode Is Enabled (Continued) Command secpolicyshow secstatsreset secstatsshow sectemppasswdreset sectemppasswdset sectransabort secversionreset Primary FCS switch Yes Yes Yes Yes Yes Yes Yes Backup FCS switch Yes Yes Yes No No Yes No Non-FCS switch No Yes Yes No No Yes Only if no FCS switch is available. Zoning Commands All Zoning commands must be executed on the Primary FCS switch, except for the cfgshow command, which can also be executed on the Backup FCS switch. Table 21 lists the Zoning commands. Table 21: Zoning Commands Executable on the Primary FCS Switch aliadd alicreate alidelete aliremove alishow cfgadd cfgclear cfgcreate cfgdelete cfgdisable cfgenable cfgremove cfgsave cfgshow cfgtransabort fazoneadd fazonecreate fazonedelete fazoneremove fazoneshow qloopadd qloopcreate qloopdelete qloopremove qloopshow zoneadd zonecreate zonedelete zoneremove zoneshow 118 Secure Fabric OS Version 1.0 User Guide