HP StorageWorks MSA1510i/MSA20 HP StorageWorks 1510i Modular Smart Array insta - Page 82

Updating MSA firmware using the SMU, HP Storage Management Utility, user guide

Page 82 highlights

IMPORTANT: If you encounter any problems during the firmware update process, stop and contact HP technical support. See for support contact information. Updating MSA firmware using the SMU NOTE: For complete information about accessing and using the SMU, see the HP Storage Management Utility user guide. 1. Determine which version firmware is currently installed on the MSA by using one of the following methods: • With the array controller powered on, press the arrow buttons on the front of the controller until the following message is displayed: 00 Array Controller Firmware ver . • From the SMU, select View MSA1510i Controller. Then, read the Device Information in the right pane of the screen and look for the Firmware Version. 2. Obtain the latest firmware files and save to a temporary location on the host: a. Navigate to the MSA1510i support page: http://www.hp.com/go/support. b. Click the title description of the download option to display important information about the update. • Click the Description tab for a brief overview about the download. • Click the Release Notes tab for detailed information about the download, including version information, compatibility information, a summary of changes, important notes, service considerations, and installation precautions. IMPORTANT: Be sure to review the online release notes and readme files for last-minute notifications about the update. c. After reviewing the release notes for update, click Download and follow the on-screen instructions to save the download bundle to a temporary directory on the server. NOTE: For downloaded ISO images, create a CD from the downloaded ISO file using a CD burning tool with the ability to burn a CD from an ISO file. Do not simply copy the ISO file to a blank CD. 3. Schedule a maintenance window for the update. 4. Ensure that there is a valid, recent backup of the system. 5. Stop all host traffic to the MSA array. 6. If the MSA has not been restarted in the last six months, power cycle the array. 82 Operation and management

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

IMPORTANT:
If you encounter any problems during the
rmware update process, stop and contact HP technical
support. See for support contact information.
Updating MSA
rmware using the SMU
NOTE:
For complete information about accessing and using the SMU, see the
HP Storage Management Utility
user guide
.
1.
Determine which version
rmware is currently installed on the MSA by using one of the following
methods:
With the array controller powered on, press the
arrow
buttons on the front of the controller until
the following message is displayed:
00 Array Controller Firmware ver <version>
.
From the SMU, select
View MSA1510i Controller
. Then, read the Device Information in the right
pane of the screen and look for the Firmware Version.
2.
Obtain the latest
rmware
les and save to a temporary location on the host:
a.
Navigate to the MSA1510i support page:
h
t
t
p
:
/
/
w
w
w
.
h
p
.
c
o
m
/
g
o
/
s
u
p
p
o
r
t
.
b.
Click the title description of the download option to display important information about the
update.
Click the
Description
tab for a brief overview about the download.
Click the
Release Notes
tab for detailed information about the download, including
version information, compatibility information, a summary of changes, important notes,
service considerations, and installation precautions.
IMPORTANT:
Be sure to review the online release notes and readme
les for last-minute noti
cations
about the update.
c.
After reviewing the release notes for update, click
Download
and follow the on-screen instructions
to save the download bundle to a temporary directory on the server.
NOTE:
For downloaded ISO images, create a CD from the downloaded ISO
le using a CD
burning tool with the ability to burn a CD from an ISO
le. Do not simply copy the
ISO
le to a blank CD.
3.
Schedule a maintenance window for the update.
4.
Ensure that there is a valid, recent backup of the system.
5.
Stop all host traf
c to the MSA array.
6.
If the MSA has not been restarted in the last six months, power cycle the array.
82