HP StorageWorks P2000 HP StorageWorks P2000 G3 MSA System Event Description Re - Page 6

port IP values. This event is - configuration

Page 6 highlights

21 Warning Vdisk verification failed during the verification process. Recommended actions • Contact technical support. Informational Vdisk verification failed immediately, was aborted by a user, or succeeded. Recommended actions • No action required. 23 Informational Vdisk creation has started. Recommended actions • No action required. 25 Informational The statistics for the indicated vdisk have been reset. Recommended actions • No action required. 27 Informational Cache parameters have been changed for the indicated vdisk. Recommended actions • No action required. 28 Informational Controller parameters have been changed. This event is logged when general configuration changes are made; for example, utility priority, remote notification settings, user interface passwords, and management port IP values. This event is not logged when changes are made to vdisk or volume configuration. Recommended actions • No action required. 31 Informational The indicated disk is no longer a global or dedicated spare. Recommended actions • No action required. 32 Informational Vdisk verification has started. Recommended actions • No action required. 33 Informational Controller time/date has been changed. This event is logged before the change happens so the event timestamp shows the "old" time. (May appear often if NTP is enabled.) Recommended actions • No action required. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

6
21
Warning
Vdisk verification failed during the verification process.
Recommended actions
Contact technical support.
Informational
Vdisk verification failed immediately, was aborted by a user, or succeeded.
Recommended actions
No action required.
23
Informational
Vdisk creation has started.
Recommended actions
No action required.
25
Informational
The statistics for the indicated vdisk have been reset.
Recommended actions
No action required.
27
Informational
Cache parameters have been changed for the indicated vdisk.
Recommended actions
No action required.
28
Informational
Controller parameters have been changed. This event is logged when general configuration changes are
made; for example, utility priority, remote notification settings, user interface passwords, and management
port IP values. This event is
not
logged when changes are made to vdisk or volume configuration.
Recommended actions
No action required.
31
Informational
The indicated disk is no longer a global or dedicated spare.
Recommended actions
No action required.
32
Informational
Vdisk verification has started.
Recommended actions
No action required.
33
Informational
Controller time/date has been changed. This event is logged before the change happens so the event
timestamp shows the “old” time. (May appear often if NTP is enabled.)
Recommended actions
No action required.