HP StorageWorks SN6000 HP StorageWorks 8/20q and SN6000 Fibre Channel CIM Agen - Page 38
Request Status Codes, Invalid Parameter: Invalid zoneset name.
View all HP StorageWorks SN6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Parameters: • ZoneSetName: [required] String naming the zoneset to be created. Must be unique within the zoning database. • ZoneSet: [out] reference to the newly constructed ZoneSet object. Returns: • 0-Success • 4-Failed • 5-Invalid Parameter: Invalid zoneset name. • 6-Access Denied: Switch is being configured by another user. Request Status Codes: • CIM_ERR_ACCESS_DENIED: User does not have authorization for this command. • CIM_ERR_INVALID_PARAMETER: One or more required parameters are missing. • CIM_ERR_NOT_FOUND: The ZoningService instance was not found. • CIM_ERR_FAILED: If the response is an error message containing an instance of CIM_Error and CIM_Error.MessageID=FC5-ZoningObject already exists. • The zoneset already exists. The path to the existing zoneset may be found in the CIM_Error.ErrorSource property. CreateZone Method will create a zone in the zoning database. The output parameter Zone contains a reference to the newly created zone object. Parameters: • ZoneName: [required] Name of zone to be created. Must be unique within the zoning database. • ZoneType: [required] Must contain the value 2=Default. A soft zone is created. • ZoneSubType: [optional] Ignored, subtype does not apply to default type. • Zone: [out] Reference to the newly constructed Zone object. Returns: • 0-Success • 4-Failed • 5-Invalid Parameter: Invalid zone name, or invalid zone type. • 6-Access Denied: Switch is being configured by another user. Request Status Codes: • CIM_ERR_ACCESS_DENIED: User does not have authorization for this command. • CIM_ERR_INVALID_PARAMETER: One or more required parameters are missing. • CIM_ERR_NOT_FOUND: The ZoningService instance was not found. • CIM_ERR_FAILED: If the response is an error message containing an instance of CIM_Error and CIM_Error.MessageID=FC5-ZoningObject already exists. • The zone already exists. The path to the existing zone may be found in the CIM_Error.ErrorSource property. AddZoneAlias Method will add a zone alias to a zone in the zoning database by creating an instance of association class MemberOfZone linking the alias and the zone together. Parameters: • Zone: [required] Reference to the zone to be added to the zonealias. • ZoneAlias: [required] Reference to the ZoneAlias to be added to the zone. Returns: • 0-Success • 4-Failed • 5-Invalid Parameter: May not configure active zone. 38 Fabric zoning classes