HP StoreOnce D2D4324 HP-StoreOnce v3.6.2 software release notes (BB852-90944, - Page 11

To check if update is successful, HP StoreOnce 2620, 4210/4220 and 4420/4430 Backup systems only

Page 11 highlights

HP StoreOnce 2620, 4210/4220 and 4420/4430 Backup systems only: Enter the following CLI commands: • system show repository which should list out the rpm file you copied over • system load package D2D_Master-3.6.2-1325.1.x86_64.rpm which will load and unpack the package (into/stage/packages) • system show packages which will show you the packages staged ready for update • system update packages which will begin the process across all nodes to upgrade and reboot the nodes To check if update is successful Wait for the system to reboot. NOTE: Depending upon the updates, this could take 50 minutes or longer for HP B6200 products and 10 minutes or longer for single node StoreOnce appliances (BBxxxn models). Once access returns to the Management interface, check that the process has completed successfully, as follows: • From the CLI: Use system show packages to check that all packages are now Installed. You should see this line in the output of system show packages: nl D2D_Master-3.6.2-1325.1.x86_64.rpm installed • From the GUI: Check on the StoreOnce screen, to ensure that the software revision number has updated to software version D2D_Master-3.6.2-1325.1. • From the GUI: Check the Event log for a confirmation message of the software upgrade. "Update D2D_Master-3.6.2-1325" completed successfully. Effective date July, 2013 Effective date 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

HP StoreOnce 2620, 4210/4220 and 4420/4430 Backup systems only:
Enter the following CLI commands:
system show repository
which should list out the rpm file you copied over
system load package D2D_Master-3.6.2-1325.1.x86_64.rpm
which will load and
unpack the package (into
/stage/packages
)
system show packages
which will show you the packages staged ready for update
system update packages
which will begin the process across all nodes to upgrade and
reboot the nodes
To check if update is successful
Wait for the system to reboot.
NOTE:
Depending upon the updates, this could take 50 minutes or longer for HP B6200 products
and 10 minutes or longer for single node StoreOnce appliances (BBxxxn models).
Once access returns to the Management interface, check that the process has completed successfully,
as follows:
From the CLI: Use
system show packages
to check that all packages are now
Installed
.
You should see this line in the output of system show packages:
nl
D2D_Master-3.6.2-1325.1.x86_64.rpm installed
From the GUI: Check on the
StoreOnce
screen, to ensure that the software revision number has
updated to software version
D2D_Master-3.6.2-1325.1
.
From the GUI: Check the Event log for a confirmation message of the software upgrade. "Update
D2D_Master-3.6.2-1325" completed successfully.
Effective date
July, 2013
Effective date
11