HP Surestore 200fx Optical Drive and Library SCSI-2 Command Reference - Page 296
Hardware Error, First FRU, Second FRU, Third FRU, Table B-5, Request Sense - Additional Sense Data
View all HP Surestore 200fx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 296 highlights
Autochanger Error Codes Autochanger Error Codes Additional Sense Data Format for Error Recovery Table B-5 Request Sense - Additional Sense Data (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Byte 7 6 5 4 3 2 1 0 40-41 42-43 44-45 46-47 48-49 50-53 54 55 56 57 58-77 Vertical Motor Actual Position Plunge Motor Commanded Position Plunge Motor Actual Position Translate Motor Commanded Position Translate Motor Actual Position Odometer Move Cap Last SCSI Reserved (0) Valid Reservd Cart (0) Tran Cart Elem Valid Reservd Cart (0) Tran Cart Elem Valid Reservd Cart (0) Tran Cart Elem Reserved (0) Cart 16 Cart 17 Reserved (0) Reserved (0) Reserved (0) Reserved (0) Hardware Error Code Determined by fault isolation, this error code indicates the cause of the failure. The values of the Hardware Error Codes are in Table B-7 on page B-19. First FRU The most likely Field Replacable Unit to be the cause of the failure. (See Table A-1 on page A-2) Second FRU The second most likely Field Replacable Unit to be the cause of the failure. (See Table A-1 on page A-2.) Third FRU The third most likely Field Replacable Unit to be the cause of the failure. (Table A-1 on page A-2.) Appendix B B-9