HP Surestore 400ex Optical Drive and Library SCSI-2 Command Reference - Page 291
Table B-2, Request Sense Data bytes 12 and 13, Sense, Qualifier, Description
View all HP Surestore 400ex manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 291 highlights
Table B-1 Table B-2 Autochanger Error Codes Request Sense Error Codes Request Sense - Sense Key Values - Byte 2, Bits 3 through 0 Sense Name Key 0BH Aborted Command Abbrev. Description AC This sense key shall be reported if a target or LUN receives a second command from the same initiator before the previous command from that initiator has completed. Request Sense Data (bytes 12 and 13) Sense Code and Qualifier Sense Key 00 00H 00 00H 0H-NS 1H-RE 04 00H 04 01H 04 02H 04 03H 0B-AC 2H-NR 2H-NR 2H-NR 04 88H 04 89H 15 01H 02-NR 4H-HE 4H-HE 1A 00H 20 00H 21 01H 5H-IR 5H-IR 5H-IR Description No additional sense information Error recovered invoked and completed (Table B-6 on page B-14) Aborted command (boot code) Autochanger becoming ready Unit must first initiate element status Fatal error - unit must be corrected manually Firmware download needed (boot code) Download checksum error Move error (Check additional sense bytes) (Table B-6 on page B-14) Invalid parameter list length Unsupported command Invalid address - (Table B-3 on page B-7) B-4 Appendix B