Table 3 Fixes in, rmware version 09.03.00
View all HP Surestore 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Description Affected models Management server FICON fault not sending field replaceable unit (FRU) change notification to EFCM. Director 2/140, 2/64 Known bad SFP reported incorrectly in Equip Check if plugged into QPM. Director 2/140, 2/64 F-port did not always login after power on. M4400 SNMP reported duplicate traps on port card insertion. Director 2/140, 2/64 Multicast packets were erroneously sent to Ethernet switch. Director 2/140 CTP processor fault event 411 sometimes occurred after CTP reset. Director 2/140 In a FICON environment, when a QPM was swapped for an XPM, or an XPM was swapped for a QPM, the prohibit dynamic connectivity masks (PDCM) of the affected ports were not cleared, and PDCMs could be configured via HAFM. Director 2/64 Attempts to activate a large zone set through OSMS when common transport (CT) authentication was enabled All occasionally was not be successful. Table 3 Fixes in firmware version 09.03.00 Description Affected models False optics mismatch error was sometimes reported when firmware was upgraded to 09.00.00 or 09.02.00 Director 2/64, ES-3032 If a device sent an OSMS Get Attached Port_Name List (GAPNL) request to a port name that did not exist in the fabric, the information unit (IU) buffer did not release, and after repeated requests would eventually deplete the IU memory. When the IU buffer pool was depleted, the fabric could segment. This was specific to this OSMS command and would occur only if the target device did not exist or did not respond to the command. Director 2/140 Vital Product Data (VPD) containing the CTP serial number and CTP part number was being deleted after inserting a spare. This information is for electronic viewing purposes only and did not impact operation of the CTP. Director 2/140, Director 2/64 IP ping over FC was not working. Sphereon 4700 Hitachi Data Systems (HDS) AMS1000 storage had problems logging in intermittently. Director 2/64 SNMP get IP command failed on Sphereon 4400 and Edge Switch 2/24, Director 2/140, Sphereon returns 127.0.0.1. 4400, 4700 Storage devices needed to register as FC-4 type in order to boot across an Edge Switch 2/24. Edge Switch 2/24 IML/IPL was required to increment the Power-on hours for the command line interface (CLI) command SHOW FRU. Director 2/64 Event 421, Informational Event, did not correctly identify the firmware version for Sphereon 4400, 4700. Sphereon 4400, 4700 HAFM was unable to manage switches after firmware upgrade due to the gateway address to the switch IP address changing. Edge Switch 2/24 6