HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 28

Connectivity Unit Table, On a read Get unknown1 is always returned. This object is writable.

Page 28 highlights

Table 2-3 Connectivity Unit Table (cont'd) Object ConnUnitProxyMaster ConnUnitPrincipal ConnUnitNumSensors connUnitStatusChangeTime (deprecated) ConnUnitConfigurationChangeTime (deprecated) ConnUnitNumRevs ConnUnitNumZones (deprecated) ConnUnitModuleId ConnUnitName Read/write ConnUnitInfo Read/write ConnUnitControl Read/write Provides yes(1) is returned yes(3) is returned if the director is the principal switch in the fabric otherwise no(2) is returned. 3 is always returned. The total time since the last status change on this switch. Not supported. 1 is always returned. 0 is always returned. Not applicable to director; an array of 16 zeros is returned. On a read (Get) the configured name for the director is returned. This object is writable. On a read (Get) the configured description of the director is returned. This object is writable. On a read (Get) unknown(1) is always returned. This object is writable. ResetConnUnitWarmStart(2), offlineConnUnit(3), and onlineConnUnit(4) controls are supported. resetConnUnitWarmStart(2) causes the director to IPL. offlineConnUnit(3) causes the director to go offline. onlineConnUnit(4) causes the director to go online. ConnUnitContact Read/write resetConnUnitColdStart is not supported. On a read (Get) the configured contact information of the director is returned. This object is writable. 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

22
±±±±±±±±)LEUH±&KDQQHO±0DQDJHPHQW±0,%
ConnUnitProxyMaster
yes(1) is returned
ConnUnitPrincipal
yes(3) is returned if the director is the principal switch in the fabric otherwise
no(2) is returned.
ConnUnitNumSensors
3 is always returned.
connUnitStatusChangeTime
(deprecated)
The total time since the last status change on this switch.
ConnUnitConfigurationChangeTime
(deprecated)
Not supported.
ConnUnitNumRevs
1 is always returned.
ConnUnitNumZones
(deprecated)
0 is always returned.
ConnUnitModuleId
Not applicable to director; an array of 16 zeros is returned.
ConnUnitName
Read/write
On a read (Get) the configured name for the director is returned. This object is
writable.
ConnUnitInfo
Read/write
On a read (Get) the configured description of the director is returned. This
object is writable.
ConnUnitControl
Read/write
On a read (Get) unknown(1) is always returned. This object is writable.
ResetConnUnitWarmStart(2), offlineConnUnit(3), and onlineConnUnit(4)
controls are supported.
resetConnUnitWarmStart(2) causes the director to IPL.
offlineConnUnit(3) causes the director to go offline.
onlineConnUnit(4) causes the director to go online.
resetConnUnitColdStart is not supported.
ConnUnitContact
Read/write
On a read (Get) the configured contact information of the director is returned.
This object is writable.
Table 2-3
Connectivity Unit Table
(cont
d)
Object
Provides