HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 28
Connectivity Unit Table, On a read Get unknown1 is always returned. This object is writable.
View all HP Surestore 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 2-3 Connectivity Unit Table (cont'd) Object ConnUnitProxyMaster ConnUnitPrincipal ConnUnitNumSensors connUnitStatusChangeTime (deprecated) ConnUnitConfigurationChangeTime (deprecated) ConnUnitNumRevs ConnUnitNumZones (deprecated) ConnUnitModuleId ConnUnitName Read/write ConnUnitInfo Read/write ConnUnitControl Read/write Provides yes(1) is returned yes(3) is returned if the director is the principal switch in the fabric otherwise no(2) is returned. 3 is always returned. The total time since the last status change on this switch. Not supported. 1 is always returned. 0 is always returned. Not applicable to director; an array of 16 zeros is returned. On a read (Get) the configured name for the director is returned. This object is writable. On a read (Get) the configured description of the director is returned. This object is writable. On a read (Get) unknown(1) is always returned. This object is writable. ResetConnUnitWarmStart(2), offlineConnUnit(3), and onlineConnUnit(4) controls are supported. resetConnUnitWarmStart(2) causes the director to IPL. offlineConnUnit(3) causes the director to go offline. onlineConnUnit(4) causes the director to go online. ConnUnitContact Read/write resetConnUnitColdStart is not supported. On a read (Get) the configured contact information of the director is returned. This object is writable. 22