HP Surestore 660ex Optical Drive and Library SCSI-2 Command Reference - Page 302
Move Error, Hardware Error, First FRU, Second FRU, Third FRU, Table B-6
View all HP Surestore 660ex manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 302 highlights
Autochanger Error Codes Autochanger Error Codes Additional Sense Data Format for Error Recovery Table B-6 Request Sense - Additional Sense Data (For models 40fx, 80ex, 125ex and 220mx ONLY) Byte 7 6 5 4 3 2 1 0 47-49 Reserved (0) 50-54 Micro-Move ID History (Table C-2 on page C-17) 55 Failed Micro-Move ID (Table C-2 on page C-17) 56 Micro-Move Error Code (Table B-11 on page B-36) 57-60 Vertical Motor Commanded Position 61-64 Vertical Motor Actual Position 65-68 Horizontal Motor Commanded Position 69-72 Horizontal Motor Actual Position 73-77 Reserved (0) Move Error Code The movement that was being performed when the error occurred. The values of the Move Error Codes are in Table B-9 on page B-29. Hardware Error Code Determined by fault isolation, this error code indicates the cause of the failure. The values of the Hardware Error Codes are in Table B-8 on page B-22. First FRU The most likely Field Replacable Unit to be the cause of the failure. (See Table A-2 on page A-4) Second FRU The second most likely Field Replacable Unit to be the cause of the failure. (See Table A-2 on page A-4.) Third FRU The third most likely Field Replacable Unit to be the cause of the failure. (See Table A-2 on page A-4.) NOTE The FRU numbers returned are indicators for the most likely cause of an error, but may not be the actual cause of a problem. Simply changing the FRU listed may or may not fix the associated problem. Appendix B B-15