HP Surestore Disk Array 12h Factory Configuration Slides for A5277AZ - Page 1
HP Surestore Disk Array 12h - And FC60 Manual
![]() |
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
A5277AZ Factory Configuration for 1 Disk Enclosure Recommended FC60 Configuration Single host, dual-controller disk array, 1 disk enclosure, 5 RAID 1 LUNs Host FC Adapter A FC Adapter B FCAL-A FCAL-B LVD SCSI Controller A Controller B FC60 Enclosure LVD SCSI Hardware Configuration - FC60 controllers connected directly to host FC adapters - One disk enclosures with ten 18 GB disk modules in each - Disk enclosure set to split-bus mode by setting option switch 1 DOWN on BCCs - Unused SCSI connectors on FC60 enclosure must be terminated - Expansion SCSI connector on disk enclosure must be terminated LUN Configuration - Five RAID 1 LUNs, comprising 2 disks each (1+1) - Each disk in the LUN is in a separate enclosure High Availability - Handles the failure of a single disk, controller, BCC, or SCSI channel - Does not handle the failure of the disk enclosure Disk Capacity - Maximum capacity ~180 GB - Usable capacity ~90 GB BCC B LUN 0 LUN 1 LUN 2 LUN 3 SC10 Disk Enclosure LUN 4 Red and Blue drives are on separate SCSI buses BCC A
![](/manual_guide/products/hewlettpackard-surestore-disk-array-12h-factory-configuration-slides-a5277az-b0f3818/1.png)