HP Workstation x1000 hp workstations general - 24in color monitor product data - Page 2

Visualize

Page 2 highlights

640x480 720x400 1280x1024 1600x1024 (16:10) 1600x1200 1920x1035 (16:9) 1920x1080 (16:9) 1920x1200 (16:10) HP VISUALIZE Monitors Resolutions / Timings Maximum resolution: 1920x1200 (76Hz only) Minimum resolution: 640x480 (60Hz only) Maximum timing: 90Hz (1280x1024) Minimum timing: 60Hz (multiple resolutions) Factory default resolution: 1920x1200 at 76Hz. Supported preset resolutions are (wide aspect formats are marked in blue): VISUALIZE EG • VISUALIZE fxe VISUALIZE • fx2-Pro VISUALIZE • fx4-Pro, fx6-Pro VISUALIZE • fx2+, fx4+, fx6+ Elsa Synergy • Oxygen GVX • • • • • • • • • • • • Video Connection Monitor has two video inputs: • One 15-pin Dsub connector (female), capable of DDC1 and DDC2Bi • One 5-receptacle BNC connector Video input can be toggled between two video inputs via a switch on the front of the monitor. One detachable 15-pin Dsub-to-Dsub video cable is provided with the monitor. To use the second video input, a BNC to Dsub video cable must be ordered (HP product number A6019A). Plug & Play Supports Display Plug&Play guidelines according to VESA DDC1, DDC2B and DDCAB. Connecting to Dsub graphics This monitor includes a 15-pin Dsub-toDsub video cable for connecting to a Dsub graphics card. To connect the monitor's BNC video input to Dsub graphics, a BNC to Dsub cable will be needed (HP product number A6019A). HP's IA-32 NT and Linux workstations use Dsub graphics. Connecting to EVC graphics PA-RISC UNIX workstations use EVC graphics cards. To connect this monitor to an EVC graphics card, use the included Dsub cable and a Dsub to EVC adapter. A Dsub to EVC adapter is included with every PA-RISC UNIX workstation when purchased. Spare Dsub to EVC adapters can be ordered using HP product number A4168A. To connect the monitor's BNC video input to Dsub graphics, a BNC to Dsub cable (A6019A) and Dsub to EVC adapter (A4168A) will be needed. Controls Front panel: power button, input select switch, reset, (OSD) option, color (OSD), screen (OSD), shape/geometry (OSD), size (OSD), center (OSD), brightness, contrast, power mode LED On Screen Display (OSD) settings: Picture size and position, brightness and contrast, shape/geometry, rotation, vertical and horizontal convergence, moiré cancellation, landing, reset to defaults, color temperature, red/green/blue intensity, demagnetize, menu language, lock buttons Color Temperature Preset temperatures: 5000K, 6500K, 9300K. Individual RGB gain/bias control can also be set. Power • AC 100-120V, 50/60 Hz., 2.2A • AC 200-240V, 50-60Hz., 1.4A • 200W maximum power consumption, less than 140W in standby mode, less than 15W in suspend mode, less than 8W in sleep mode, 0W when power off. • VESA, DPMS, NUTEK compliant • EPA Energy Star compliant November 22, 1999 www.hp.com

  • 1
  • 2
  • 3

November 22, 1999
www.hp.com
Resolutions / Timings
Maximum resolution:
1920x1200 (76Hz only)
Minimum resolution:
640x480 (60Hz only)
Maximum timing:
90Hz (1280x1024)
Minimum timing:
60Hz (multiple resolutions)
Factory default resolution:
1920x1200 at 76Hz.
Supported preset resolutions are
(wide aspect
formats are marked in blue):
640x480
720x400
1280x1024
1600x1024 (16:10)
1600x1200
1920x1035 (16:9)
1920x1080 (16:9)
1920x1200 (16:10)
VISUALIZE EG
VISUALIZE fxe
VISUALIZE
fx2-Pro
VISUALIZE
fx4-Pro, fx6-Pro
VISUALIZE
fx2+, fx4+, fx6+
Elsa Synergy
Oxygen GVX
Video Connection
Monitor has two video inputs:
One 15-pin Dsub connector (female), capable
of DDC1 and DDC2Bi
One 5-receptacle BNC connector
Video input can be toggled between two video
inputs via a switch on the front of the monitor.
One
detachable 15-pin Dsub-to-Dsub video cable is
provided with the monitor.
To use the second video
input, a BNC to Dsub video cable must be ordered
(HP product number A6019A).
Plug & Play
Supports Display Plug&Play guidelines according
to VESA DDC1, DDC2B and DDCAB.
Connecting to Dsub graphics
This monitor includes a 15-pin Dsub-to-
Dsub video cable for connecting to a Dsub
graphics card.
To connect the monitor’s
BNC video input to Dsub graphics, a BNC
to Dsub cable will be needed (HP product
number A6019A).
HP’s IA-32 NT and Linux
workstations use Dsub graphics.
Connecting to EVC graphics
PA-RISC UNIX workstations use EVC
graphics cards.
To connect this monitor to
an EVC graphics card, use the included
Dsub cable and a
Dsub to EVC adapter
.
A Dsub to EVC adapter is included with
every PA-RISC UNIX workstation when
purchased.
Spare Dsub to EVC adapters
can be ordered using HP product number
A4168A.
To connect the monitor’s BNC
video input to Dsub graphics, a BNC to
Dsub cable (A6019A) and Dsub to EVC
adapter (A4168A) will be needed.
Controls
Front panel:
power button, input select
switch, reset, (OSD) option, color (OSD),
screen (OSD), shape/geometry (OSD), size
(OSD), center (OSD), brightness, contrast,
power mode LED
On Screen Display (OSD) settings:
Picture size and position, brightness and
contrast, shape/geometry, rotation, vertical
and horizontal convergence, moiré
cancellation, landing, reset to defaults, color
temperature, red/green/blue intensity,
demagnetize, menu language, lock buttons
Color Temperature
Preset temperatures:
5000K, 6500K, 9300K.
Individual RGB
gain/bias control can also be set.
Power
AC 100-120V, 50/60 Hz., 2.2A
AC 200-240V, 50-60Hz., 1.4A
200W maximum power consumption,
less than 140W in standby mode, less
than 15W in suspend mode, less than
8W in sleep mode, 0W when power off.
VESA, DPMS, NUTEK compliant
EPA Energy Star compliant
HP
VISUALIZE
Monitors