HP rp2450 HP DLPI Programmer's Guide - Page 78
DL_SUBS_BIND_REQ, Reasons for Failure, Format, Parameters
View all HP rp2450 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
DLPI Primitives Local Management Primitives Reasons for Failure DL_OUTSTATE The primitive was issued from an invalid state. DL_SYSERR A system error has occurred and the UNIX system error is indicated in the DL_ERROR_ACK. The UNIX error returned may be set to (not limited to) errors listed in Table 2-2 on page 71. DL_SUBS_BIND_REQ Requests the DLS provider bind a subsequent DLSAP to the stream. The DLS user must identify the address of the subsequent DLSAP to be bound to the stream. Format The message consists of one M_PROTO message block, which contains the following structure. typedef struct { ulong dl_primitive; ulong dl_subs_sap_offset; ulong dl_subs_sap_length; ulong dl_subs_bind_class; } dl_subs_bind_req_t; Parameters dl_primitive DL_SUBS_BIND_REQ dl_subs_sap_offset offset of the DLSAP from the beginning of the M_PROTO block. dl_subs_sap_length length of the specified DLSAP. dl_subs_bind_class specifies either peer or hierarchical addressing. 78 Chapter 2