Hikvision DS-KH6320-WTE1 Operation Manual - Page 33
Tes°ng
View all Hikvision DS-KH6320-WTE1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Network Indoor Station Operation Guide 2-Wire Model Quantity Power DS-KD8003IME2 1 4 W DS-KD-DIS 1 2.5 W DS-KD-KP 2 2 W DS-KD-M 2 1.6 W / / Total: 10.1 W Because 10.1 W ≤ 16 W, we can support powering this device through KAD706 channel 6 or KAD704 channel 4. 2-Wire Model Quantity Power DS-KD8003-IME2 1 4 W DS-KD-M 1 0.8 W DS-KD-KK 12 9.6 W / / Total: 14.4 W Because 14.4 W ≤ 16 W, we can support powering this device through KAD706 channel 6 or KAD704 channel 4. Wire Testing Standards ● When there are multiple cores in one parallel line, only one pair of closed cores are allowed to transmit signal. It is not allowed to use multiple pair of cores in one cable to transmit signal. ● When using parallel lines, it is suggested to use those with shielding layer. If dual core or multiple core parallel lines without shielding layer are routed, stability of signal transmission can be effected. You need to run a test before installation. ● Impedance of twist pair in network cable are over 42 Ω/100 m, so network cable cannot transmit enough power to indoor station. Network cable is not allowed to use during installation. ● Strong electricity and weak electricity cannot be wired in the same route, they need to be wired separately and the distance should be more than 0.5 meter. 22