Hitachi CP-X2510N User Manual - Page 9
Communicaion settings
![]() |
UPC - 050585151697
View all Hitachi CP-X2510N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
RS-232C Communication (continued) Communicaion settings 1. Protocol 19200bps,8N1 2. Command format ("h" shows hexadecimal) Byte Number 0 1 2 3 4 5 6 7 8 9 10 11 12 Command Header Data Action Header Data code Packet size LH LH CRC flag LH Action LH Type LH Setting code LH Change setting to desired value [(cL)(cH)] by [(eL)(eH)]. (aL) (aH) 01h 00h (bL) (bH) (cL) (cH) Read projector internal setup value [(bL) (bH)] . (aL) (aH) 02h 00h (bL) (bH) 00h 00h Increment setup value [(bL)(bH)] by 1. BEh EFh 03h 06h 00h (aL) (aH) 04h 00h (bL) (bH) 00h 00h Decrement setup value [(bL)(bH)] by 1. (aL) (aH) 05h 00h (bL) (bH) 00h 00h Run a command [(bL)(bH)]. (aL) (aH) 06h 00h (bL) (bH) 00h 00h [Header code] [Packet] [Data size] Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 ~ 4. [CRC flag] For byte number 5, 6, refer to RS-232C Communication / Network command table (&17). [Action] Set functional code to byte number 7, 8. = [01h, 00h], = [02h, 00h], = [04h, 00h] = [05h, 00h], = [06h, 00h] Refer to the Communication command table (&above). [Type] [Setting code] For byte number 9 ~ 12, refer to RS-232C Communication / Network command table (&17). 9
![](/manual_guide/products/hitachi-cpx3010-user-manual-4939ccd/9.png)