Hitachi CPX265 Technical Manual - Page 12

OVER SCAN Reset

Page 12 highlights

RS-232C Communication (continued) Names Operation Type ASPECT Set OVER SCAN OVER SCAN Reset V POSITION V POSITION Reset H POSITION H POSITION Reset H PHASE H SIZE H SIZE Reset AUTO ADJUST COLOR SPACE Set COMPONENT Set C-VIDEO FORMAT Set S-VIDEO FORMAT Set 12 4:3 16:9 14:9 SMALL NORMAL Get Get Increment Decrement Execute Get Increment Decrement Execute Get Increment Decrement Execute Get Increment Decrement Get Increment Decrement Execute Execute AUTO RGB SMPTE240 REC709 REC601 Get COMPONENT SCART RGB Get AUTO NTSC PAL SECAM NTSC4.43 M-PAL N-PAL Get AUTO NTSC PAL SECAM NTSC4.43 M-PAL N-PAL Get Header BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 BE EF 03 06 00 CRC 9E D0 0E D1 CE D6 FE D1 5E DD AD D0 91 70 F7 70 26 71 EC D9 0D 83 6B 83 BA 82 E0 D2 F1 82 97 82 46 83 1C D3 49 83 2F 83 FE 82 B5 82 D3 82 02 83 68 D2 91 D0 0E 72 9E 73 6E 73 FE 72 CE 70 3D 72 4A D7 DA D6 79 D7 A2 70 C2 74 52 75 52 70 62 77 C2 71 32 74 31 76 E6 70 86 74 16 75 16 70 26 77 86 71 76 74 75 76 Command Data Action Type Setting Code 01 00 01 00 01 00 01 00 01 00 02 00 02 00 04 00 05 00 06 00 02 00 04 00 05 00 06 00 02 00 04 00 05 00 06 00 02 00 04 00 05 00 02 00 04 00 05 00 06 00 06 00 01 00 01 00 01 00 01 00 01 00 02 00 01 00 01 00 02 00 01 00 01 00 01 00 01 00 01 00 01 00 01 00 02 00 01 00 01 00 01 00 01 00 01 00 01 00 01 00 02 00 08 20 08 20 08 20 08 20 08 20 08 20 09 22 09 22 09 22 27 70 00 21 00 21 00 21 02 70 01 21 01 21 01 21 03 70 03 21 03 21 03 21 02 21 02 21 02 21 04 70 0A 20 04 22 04 22 04 22 04 22 04 22 04 22 17 20 17 20 17 20 11 22 11 22 11 22 11 22 11 22 11 22 11 22 11 22 12 22 12 22 12 22 12 22 12 22 12 22 12 22 12 22 00 00 01 00 09 00 02 00 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 02 00 03 00 04 00 00 00 00 00 01 00 00 00 0A 00 04 00 05 00 09 00 02 00 08 00 07 00 00 00 0A 00 04 00 05 00 09 00 02 00 08 00 07 00 00 00

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

±2
Names
Operation Type
Header
Command Data
CRC
Action
Type
Setting Code
ASPECT
Set
4:3
BE EF
03
06 00
9E D0
01 00
08 20
00 00
16:9
BE EF
03
06 00
0E D1
01 00
08 20
01 00
14:9
BE EF
03
06 00
CE D6
01 00
08 20
09 00
SMALL
BE EF
03
06 00
FE D1
01 00
08 20
02 00
NORMAL
BE EF
03
06 00
5E DD
01 00
08 20
10 00
Get
BE EF
03
06 00
AD D0
02 00
08 20
00 00
OVER SCAN
Get
BE EF
03
06 00
91 70
02 00
09 22
00 00
Increment
BE EF
03
06 00
F7 70
04 00
09 22
00 00
Decrement
BE EF
03
06 00
26 71
05 00
09 22
00 00
OVER SCAN Reset
Execute
BE EF
03
06 00
EC D9
06 00
27 70
00 00
V POSITION
Get
BE EF
03
06 00
0D 83
02 00
00 21
00 00
Increment
BE EF
03
06 00
6B 83
04 00
00 21
00 00
Decrement
BE EF
03
06 00
BA 82
05 00
00 21
00 00
V POSITION Reset
Execute
BE EF
03
06 00
E0 D2
06 00
02 70
00 00
H POSITION
Get
BE EF
03
06 00
F1 82
02 00
01 21
00 00
Increment
BE EF
03
06 00
97 82
04 00
01 21
00 00
Decrement
BE EF
03
06 00
46 83
05 00
01 21
00 00
H POSITION Reset
Execute
BE EF
03
06 00
1C D3
06 00
03 70
00 00
H PHASE
Get
BE EF
03
06 00
49 83
02 00
03 21
00 00
Increment
BE EF
03
06 00
2F 83
04 00
03 21
00 00
Decrement
BE EF
03
06 00
FE 82
05 00
03 21
00 00
H SIZE
Get
BE EF
03
06 00
B5 82
02 00
02 21
00 00
Increment
BE EF
03
06 00
D3 82
04 00
02 21
00 00
Decrement
BE EF
03
06 00
02 83
05 00
02 21
00 00
H SIZE Reset
Execute
BE EF
03
06 00
68 D2
06 00
04 70
00 00
AUTO ADJUST
Execute
BE EF
03
06 00
91 D0
06 00
0A 20
00 00
COLOR SPACE
Set
AUTO
BE EF
03
06 00
0E 72
01 00
04 22
00 00
RGB
BE EF
03
06 00
9E 73
01 00
04 22
01 00
SMPTE240
BE EF
03
06 00
6E 73
01 00
04 22
02 00
REC709
BE EF
03
06 00
FE 72
01 00
04 22
03 00
REC601
BE EF
03
06 00
CE 70
01 00
04 22
04 00
Get
BE EF
03
06 00
3D 72
02 00
04 22
00 00
COMPONENT
Set
COMPONENT
BE EF
03
06 00
4A D7
01 00
17 20
00 00
SCART RGB
BE EF
03
06 00
DA D6
01 00
17 20
01 00
Get
BE EF
03
06 00
79 D7
02 00
17 20
00 00
C-VIDEO FORMAT
Set
AUTO
BE EF
03
06 00
A2 70
01 00
11 22
0A 00
NTSC
BE EF
03
06 00
C2 74
01 00
11 22
04 00
PAL
BE EF
03
06 00
52 75
01 00
11 22
05 00
SECAM
BE EF
03
06 00
52 70
01 00
11 22
09 00
NTSC4.43
BE EF
03
06 00
62 77
01 00
11 22
02 00
M-PAL
BE EF
03
06 00
C2 71
01 00
11 22
08 00
N-PAL
BE EF
03
06 00
32 74
01 00
11 22
07 00
Get
BE EF
03
06 00
31 76
02 00
11 22
00 00
S-VIDEO FORMAT
Set
AUTO
BE EF
03
06 00
E6 70
01 00
12 22
0A 00
NTSC
BE EF
03
06 00
86 74
01 00
12 22
04 00
PAL
BE EF
03
06 00
16 75
01 00
12 22
05 00
SECAM
BE EF
03
06 00
16 70
01 00
12 22
09 00
NTSC4.43
BE EF
03
06 00
26 77
01 00
12 22
02 00
M-PAL
BE EF
03
06 00
86 71
01 00
12 22
08 00
N-PAL
BE EF
03
06 00
76 74
01 00
12 22
07 00
Get
BE EF
03
06 00
75 76
02 00
12 22
00 00
RS-232C Communication (continued)