Hitachi NV50AA Instruction Manual - Page 11
Hitachi NV50AA - 1-1/4" to 2" x Manual
UPC - 717709002180
View all Hitachi NV50AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Hold the Nailer downward and pull the trigger. u THE NAILER MUST NOT OPERATE. T.11 ADJUSTING AIR PRESSURE L\ WARNING Pull Trigger (3) With finger off the trigger, depress the push lever against the workpiece. u THE NAILER MUST NOT OPERATE. LL Depress Push Lever f'\ Do not pull Trigger (4) Without touching the trigger, depress the push lever against the workpiece. Pull the trigger. u THE NAILER MUST OPERATE. (5) With the Nailer off the workpiece, pull the trigger. Depress the push lever against the workpiece. u THE NAILER MUST OPERATE. (6) If no abnormal operation is observed, you may load nails in the Nailer. Drive nails into the workpiece that is the same type to be used in the actual application. u THE NAILER MUST OPERATE PROPERLY. • Do not exceed 120 psi (8.3 bar 8.5 kgf/cm9. Adjust the air pressure at recommended operating pressure 70-120 psi (4.9-8.3 bar 5-8.5 kgf/cm2) according to the length of nails and the hardness of workpiece. The correct air pressure is the lowest pressure which will do the job. Using the Nailer at a higher than required air pressure unnecessarily over stresses the Nailer. LOADING NAILS ,L\ WARNING • When loading nails into Nailer, 1) do not depress trigger; 2) do not depress push lever; and 3) keep Nailer pointed downward. (1) Press the magazine stopper and open the magazine cover. Magazine Stopper Magazine Cover (2) Place the nail coil in the magazine. Insert the first nail into the magazine opening. Magazine Opening First Nail Magazine - 11 -