Hitachi UT47X902 Owners Guide - Page 12

SAFETY PRECAUTIONS continued, Wall Mount Setup - 47

Page 12 highlights

SAFETY PRECAUTIONS (continued) Wall Mount Setup 1 Remove the Stand Base from the Monitor About the Installation This product is heavy and should be carried by at least 2 people. Please make sure screws are WARNING tightened properly. The torque should be 1.8~3.0 N.m (18~30 kgf.cm). Keep the screws. They may CAUTION be used for the Wall Mount installation. Remove the 4 screws and raise straight up from tabletop stand. 2 Install the Wall Mount Brackets on the Monitor using 4 screws (Screws Specification is shown below ). Screw Length (A) Screw Mounting Holes (4 places).Don't use the original flat head screws (A) that Insertion length (B) comes in the monitor, for the Wall Mount Braket. The length is not long enough. Spring Washer (C) Plane Washer (D) Wall Mount Bracket (E) Wall Mount Brackets For Wall Mount assembly; please refer to the Installation Manual of the Wall Mount Unit. If the Wall Mount Bracket thickness is 1~3 mm. the original screws removed from the stand base can be used for the Wall Mount installation. Example(37"/47") Example(42") : A = B+C+D+E A = B+C+D+E A: 11~13 mm. A: 12~16 mm. B: 7~9 mm. B: 8~12 mm. C: 1 mm. C: 1 mm. D: 1 mm. D: 1 mm. E: 2 mm. E: 2 mm. The screw type :Theread ISO M5 (Metric type, do not use Standard type). CAUTION Insertion length (B) of the screws must be within 7~9 mm(37"/47") or 8~12 mm(42"). If the 7 mm(37"/47") or 8 mm(42"), the weight can not be maintained. If the length is more than 9 length is less than mm(37"/47") or 12 mm(42"), a space is created between the Wall Mount Bracket and the Monitor. This length is very important. 3 Tips to consider for the location of the Monitor. Do not block the ventilation holes. In More than 30 cm (1'). addition please keep a cetain distance around and make sure not to obstruct ventilation. More than 10 cm (4"). Keep more than 2 cm (0.8") Blocking the ventilation holes might cause fire or defect. away from the wall. CAUTION If you purchased the Wall Mount unit, please ask for a professional installer. Do not install by yourself. This ultrathin unit features an advanced ventilation system configured for vertical installation. A knowledgeable and experienced professional technician can perform other mounting or installation orientations (e.g., horizontal, tilted) provided that you specifically inform the technician of the unit's specialized ventilation needs. Call 800-HITACHI for additional info and guidance. Although this LCD Monitor can be installed using a variety of third party wall mounting brackets/devices, such CAUTION third party brackets/devices have not been tested or approved by Hitachi for use or compatibility with this LCD Monitor. Accordingly, Hitachi accepts no responsability or liability for any injuries or property damage resulting from the use of such third party brackets/devices. Hitachi strongly advises that any installation of this LCD Monitor using wall mounting brackets/devices be performed only by a qualified and experienced television installation technician who has completed a thorough evaluation of: a) the weight-bearing strength and stability of the intended wall mount surface; and b) the weight-bearing strength and compatibility of the intended wall mount brackets/device. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

11
CAUTION
Although this LCD Monitor can be installed using a variety of third party wall mounting brackets/devices, such
third party brackets/devices have not been tested or approved by Hitachi for use or compatibility with this
LCD Monitor. Accordingly, Hitachi accepts no responsability or liability for any injuries or property damage
resulting from the use of such third party brackets/devices. Hitachi strongly advises that any installation of this LCD Monitor
using wall mounting brackets/devices be performed only by a qualified and experienced television installation technician who
has completed a thorough evaluation of:
a) the weight-bearing strength and stability of the intended wall mount surface; and
b) the weight-bearing strength and compatibility of the intended wall mount brackets/device.
Do not block the
ventilation holes. In
addition please keep a
cetain distance around
and make sure not to
obstruct ventilation.
Blocking the ventilation
holes might cause fire or
defect.
More than
30 cm (1').
More than
10 cm (4").
Keep
more than
2 cm (0.8")
away from
the wall.
Remove the Stand Base from the Monitor
Install the Wall Mount Brackets on the Monitor using 4 screws (Screws
Specification is shown below ).
Tips to consider for the location of the Monitor.
1
SAFETY PRECAUTIONS (continued)
Wall Mount Setup
2
3
About the Installation
This product is heavy and should be
carried by at least 2 people.
Keep the screws. They may
be used for the Wall Mount
installation.
CAUTION
Please make sure screws are
tightened properly.
The torque should be 1.8~3.0
N.m (18~30 kgf.cm).
WARNING
Remove the 4 screws and raise straight up from tabletop stand.
Screw Mounting Holes (4 places).Don't
use the original flat head screws (A) that
comes in the monitor, for the Wall Mount
Braket. The length is not long enough.
Wall Mount Brackets
Screw Length (A)
Insertion length (
B)
Spring Washer (C)
Plane Washer (D)
Wall Mount Bracket (E)
Example(37"/47")
A = B+C+D+E
A: 11~13 mm.
B: 7~9 mm.
C: 1 mm.
D: 1 mm.
E: 2 mm.
The screw type :Theread ISO M5 (Metric
type, do not use Standard type).
CAUTION
For Wall Mount assembly; please refer to the Installation Manual of the
Wall Mount Unit.
If the Wall Mount Bracket thickness is 1~3 mm. the original screws
removed from the stand base can be used for the Wall Mount installation.
Insertion length (
B
) of the screws must be within 7~9 mm(37"/47") or 8~12 mm(42"). If the length is less than
7 mm(37"/47") or 8 mm(42"), the weight can not be maintained. If the length is more than 9 mm(37"/47") or 12
mm(42"), a space is created between the Wall Mount Bracket and the Monitor. This length is
very important
.
CAUTION
If you purchased
the Wall Mount unit,
please ask for a professional
installer. Do not install by yourself.
This ultrathin unit features
an advanced ventilation
system configured for
vertical installation. A
knowledgeable and
experienced professional
technician can perform
other mounting or
installation orientations
(e.g., horizontal, tilted)
provided that you
specifically inform the
technician of the unit's
specialized ventilation
needs. Call 800-HITACHI
for additional info and
guidance.
Example(42") :
A = B+C+D+E
A: 12~16 mm.
B: 8~12 mm.
C: 1 mm.
D: 1 mm.
E: 2 mm.