HoMedics BPA-200 User Manual - Page 16
Troubleshooting, Specifications
View all HoMedics BPA-200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
TROUBLESHOOTING If any abnormality arises during use, please check the following points SYMPTOMS POSSIBLE CAUSES CORRECTION Unit does not turn on when Batteries have the START/STOP run down. button is pushed. Battery polarities have been positioned incorrectly. Replace them with four new AA alkaline batteries. Re-insert the batteries in the correct positions. EE measurement error Cuff has been placed symbol shown on display or incorrectly. the blood pressure value is displayed excessively low Did you talk or move (or high). during measurement? Shaking of the arm with the cuff on. Wrap the cuff properly so that it is positioned correctly. Measure again. Keep arm steady during measurement. Er error symbol shown on display - measurement result exceeds measurement range. Did you move during measurement? Shaking of the arm with the cuff on. Measure again. Do not move during measurement. E1 error symbol shown on Air circuit abnormality. Cuff Check cuff connection. display tube may not be plugged Measure again. into monitor correctly. E2 error symbol shown on display E3 error symbol shown on display CA Appears on display Inflation pressure exceeding Switch the unit off, then 300 mmHg. measure again. Data error. Remove and reload the batteries. Recalibration alert. Refer to page 25 for more information. Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you disassemble or attempt to repair the unit by yourself. Contact information for HoMedics Consumer Relations Department can be found on the warranty page. 29 SPECIFICATIONS Power Source: Measurement Method: Four 1.5V DC (AA) batteries or supplied 12V DC AC adapter Oscillometric Measurement Range: Pressure: 40~250 millimeters mercury (mmHg) Pulse: 40~199 beats/minute Accuracy: Pressure: ±3 mmHg Pulse: ±5% of reading Pressure Sensor: Semi-conductor Inflation: Deflation: Memory Capacity: Pump driven Automatic Pressure release valve 60 memories for each User (120 total) Auto-shut-off: Operation Environment: Storage Environment: Weight: 1 minute after last button operation Temperature: 50°F~104°F (10°C ~40°C) Humidity: 40~85% RH max. Temperature: 14°F~140°F (-10°C~60°C) Humidity: 10~90% RH max. 0.80 lbs (without batteries) Arm Circumference: 8.7"-18.1" (22-46cm) Dimensions: 4.5"(L) x 5.9"(W) x 3"(H) 114mm(L) x 150mm(W) x 76mm(H) Type BF Device and cuff are designed to provide special protection against electrical shocks. Note: These specifications are subject to change without notice. 30