Holmes CBAP520 Instruction Manual - Page 2

Important Safeguards, Important Safeguards, Please Read And Save, These Important, Safety

Page 2 highlights

IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include: 1. Read all instructions before using the appliance. 2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 3. If the filter is covered by a bag when shipped, remove plastic bag before use. 4. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiators, stoves, or heaters. 5. To protect against electrical hazards, DO NOT immerse the appliance in water or other liquids. Do not use near water. 6. Close supervision is necessary when any appliance is used by or near children, or disabled persons. 7. Always unplug the air purifier before moving or cleaning the unit, opening the grill, changing the filters and whenever the unit is not in use. To disconnect the unit, be sure to pull the plug and not the cord. 8. NEVER drop or insert any objects into the openings of the unit. 9. DO NOT operate any appliance with a damaged cord or plug. 10. If the motor fan fails to operate or the unit has been dropped or damaged in any manner, return appliance to manufacturer for examination. 11. Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments may cause hazards and is not recommended or sold by Jarden Consumer Solutions. 12. DO NOT use outdoors. 13. NEVER place on a soft surface such as a bed or sofa as this could cause the unit to tip over and block the air inlet or outlet grills. 14. Keep unit away from heated surfaces and open flames. 15. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. 16. DO NOT place anything on top of unit. 17. NEVER use detergents, gasoline, glass purifier, furniture polish, paint thinner, or other household solvents to clean any part of the appliance. 18. Always turn the appliance off before unplugging it. 19. The ionizer in this appliance produces less ozone than the UL established limits of 50ppb (parts per billion). However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the fan on. 20. This appliance should only be used in a room with temperatures between 40° F and 110° F. 21. WARNING: To reduce the risk of fire or electric shock, DO NOT use this appliance with any solid-state speed control device. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY. IMPORTANT SAFEGUARDS FEATURES CORD SAFETY • The length of cord used on this appliance was selected to reduce tangling and tripping hazards. • If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the air cleaner (see rating label marked on product). • Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over. GET TO KNOW YOUR AIR CLEANER This unit is compatible with all Aer1® Filters. This allows you to choose the filter that is just right for you. Below is information on each filter: TOTAL AIR - Advanced Dust Eliminating Technology ODOR ELIMINATOR - 10x the odor fighting power ALLERGEN REMOVER - True HEPA technology improves air quality for allergy sufferers ALLERGEN PERFORMANCEPLUS - True HEPA technology improves air quality for allergy sufferers SMOKE GRABBER - 99% effective at removing smoke from the air steam (*as small as 0.3 microns from air passing through the filter). IONIZER This appliance has an optional ionizer feature which, when turned on, releases negative ions into outgoing filtered air to help the air purification process. What Are Ions? Ions are tiny particles that carry a positive or negative charge. They exist naturally around us: in the air, water, and ground. Both positive and negative ions are colorless, odorless, and completely harmless. How Does The Ionizer Work? Negative ions help air purification by attaching themselves to very small airborne particles in the room. These particles take on a negative charge and may join with positively charged particles such as dust, pollen, smoke, and pet dander to form larger particles. These larger particles are then more easily captured by the filter system. Important Notes: Your ionizer may produce an occasional popping or cracking sound. This is normal and occurs when a small buildup of ions is discharged. After extended use, you may notice dust around the grills or front panel. This is caused by negative ions exiting the air outlet, evidence of the ionizer's air cleaning effectiveness. You can remove the dust with a soft brush or clean, damp cloth. Larger particles may be attracted to positively charged surfaces throughout the home, like walls or floors. • This may occur more frequently when the filter is nearing the end of its usable product life and is unable to capture as many charged particles. • Excessive amounts of pet dander, dust, or smoke may decrease the life expectancy of the filters and interfere with the ionization process. To help prevent particles from attracting to surfaces throughout your home: • You may want to run the ionizer less often. • Check the condition of filters more frequently. CAUTION: The ionizer in this appliance produces less ozone than the UL established limits of 50ppb. However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the fan on. IMPORTANT: Always check the condition of the Aer1® filters at the recommended intervals and replace filters if necessary (See FILTER REPLACEMENT INSTRUCTIONS). Using the ionizer with dirty filters may result in dirty particles exiting the air cleaner and attracting to walls, carpets, furniture, or other household objects. These dirty particles may prove difficult to remove. FEATURES - OPERATIONS FILTER CHECK INDICATOR Your Air Cleaner includes Aer1® Allergen PerformancePlus Filters, specially designed to improve air quality for allergy sufferers! The Aer1® Allergen PerformancePlus Filters last 12 months. See back panel for other filter options. The Filter Check Indicator is designed to remind you to check and change your filters every 12 months. To reset the Filter Check Indicator, press the Filter Reset Button ( ) for 3 seconds. The Filter Check Indicator will flash 6 times to indicate that it has been reset. Figure 1 A B CD E THREE SPEED SETTINGS For optimum air filtration, operate your Bionaire® air cleaner continuously on the highest (3) setting. Its rugged motor has been designed to give many years of use. For quieter operation (such as in a bedroom), select the lowest (1) setting. BEFORE USE 1. Carefully unpack your air cleaner. 2. Select a firm, level surface with no obstructions to the air inlets or outlets. 3. Access your Aer1® Filters. If the filters are covered by bags when shipped, remove plastic bags before use and place filters into unit. (Reference FILTER REPLACEMENT INSTRUCTIONS). CONTROL PANEL (close-up) FG H I A. Filtered Air Outlet B. Control Panel C. Aer1® Filters D. Washable Foam Pre-filter E. Air Inlet Grill F. Ionizer Button/Light () G. Filter Reset Button/ Light ( ) H. Speed Control Buttons/Lights (1-2-3) I. Power Button ( ) CBAP520_12EM1.indd 2 FEATURES - OPERATIONS CLEANING / MAINTENANCE OPERATING INSTRUCTIONS IMPORTANT: • REMOVE ALL PLASTIC BAGS FROM FILTERS BEFORE USE. • DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL. 1. Plug into a 120V AC electrical outlet. 2. Press the Power Button ( ). The air cleaner will turn onto HIGH, the High (3) speed button light will illuminate letting you know the power is on and running at High setting. To turn the air cleaner off at any time, press the power button and all button lights will go off. 3. You can then select the desired speed setting. This air cleaner has three speed settings. You can select from HIGH (3), MEDIUM (2), or LOW (1) by pressing the desired operating speed control button on the control panel. The corresponding button light will illuminate to indicate which setting being selected. 4. To release negative ions into the filtered air, press the Ionizer Button ( ) and the button light will illuminate. 5. This unit has a built in memory function that will recall the last setting from the previous use. This memory function will only operate if the unit remains plugged in between uses. NOTE: The ionizer will not work unless the unit is running. CLEANING AND MAINTENANCE Cleaning the unit: 1. Turn off and unplug the air cleaner. 2. The outside of the unit can be cleaned with a soft, clean damp cloth. 3. The air inlet grill (see figure 1) can be cleaned with a soft, clean damp cloth. 4. The filtered air outlet can be cleaned of dust with a small soft brush. 5. If you wish to clean the inside of the air cleaner, please only use a dry, soft cloth to wipe it down. DO NOT WASH the Aer1® filters. The Pre-filter (D) can be washed by using a mild dish soap and water. Rinse thoroughly. Allow to air dry completely prior to reinstalling into the Air Inlet Grill (E). 6. NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the air cleaner. WARNING: Do not allow moisture to come in contact with the main housing of the air cleaner. FILTER REPLACEMENT INSTRUCTIONS Every few weeks, check the condition of filters. Filter life will vary, depending on air quality and usage (see below). Under normal conditions of continuous use, the Aer1® Total Air, Odor and Smoke Filter will last 4 months while the Allergen and Allergen PerformancePlus Filter will last 12 months. After approximately 12 months of operation, the Filter Check Indicator Light ( ) will illuminate to alert you to service the filter. To replace your filter: 1. Turn off and unplug the air cleaner before attempting to replace the filters. 2. Remove each of the filters from the unit by pulling them gently towards you. 3. Discard the Aer1® filters. DO NOT attempt to clean them. 4. Remove protective plastic bags and install new Aer1® filters into the unit. Figure 2 NOTE: Ensure proper assembly of the filter clip to the filter. Attach the filter clip and filter assembly to the air cleaner hang tabs: • Make sure the hang tab is securely in place. Align the Figure 3 clip on the side of the Aer1® filter with the rails on the inside of the unit. Gently slide the filter onto the rail (see Figures 2 and 3). 5/15/13 2:17 PM

  • 1
  • 2

FILTER CHECK INDICATOR
Your Air Cleaner includes Aer1
®
Allergen PerformancePlus
Filters, specially designed to improve air quality for
allergy sufferers! The Aer1
®
Allergen PerformancePlus
Filters last 12 months. See back panel for other filter
options.
The Filter Check Indicator is designed to remind you to
check and change your filters every 12 months. To reset
the Filter Check Indicator, press the Filter Reset Button
(
) for 3 seconds. The Filter Check Indicator will flash
6 times to indicate that it has been reset.
THREE SPEED SETTINGS
For optimum air filtration, operate your Bionaire
®
air
cleaner continuously on the highest (3) setting. Its rugged
motor has been designed to give many years of use. For
quieter operation (such as in a bedroom), select the
lowest (1) setting.
BEFORE USE
1.
Carefully unpack your air cleaner.
2.
Select a firm, level surface with no obstructions to the
air inlets or outlets.
3.
Access your Aer1
®
Filters. If the filters are covered by
bags when shipped, remove plastic bags before use
and place filters into unit. (Reference
FILTER
REPLACEMENT INSTRUCTIONS
).
IMPORTANT SAFEGUARDS
IMPORTANT SAFEGUARDS -
FEATURES
CORD SAFETY
The length of cord used on this appliance was
selected to reduce tangling and tripping hazards.
If a longer cord is necessary, an approved extension
cord may be used. The electrical rating of the
extension cord must be equal to or greater than the
rating of the air cleaner (see rating label marked on
product).
Care must be taken to arrange the extension cord so
that it will not drape over the countertop or tabletop
where it can be pulled on by children or accidentally
tripped over.
GET TO KNOW YOUR AIR CLEANER
This unit is compatible with all Aer1
®
Filters. This allows
you to choose the filter that is just right for you. Below is
information on each filter:
TOTAL AIR
- Advanced Dust Eliminating Technology
ODOR ELIMINATOR
- 10x the odor fighting power
ALLERGEN REMOVER
- True HEPA technology
improves air quality for allergy sufferers
ALLERGEN PERFORMANCEPLUS
- True HEPA
technology improves air quality for allergy sufferers
SMOKE GRABBER
- 99% effective at removing smoke
from the air steam (*as small as 0.3 microns from air
passing through the filter).
IONIZER
This appliance has an optional ionizer feature which,
when turned on, releases negative ions into outgoing
filtered air to help the air purification process.
What Are Ions?
Ions are tiny particles that carry a positive or negative
charge. They exist naturally around us: in the air, water,
and ground. Both positive and negative ions are colorless,
odorless, and completely harmless.
How Does The Ionizer Work?
Negative ions help air purification by attaching
themselves to very small airborne particles in the room.
These particles take on a negative charge and may join
with positively charged particles such as dust, pollen,
smoke, and pet dander to form larger particles. These
larger particles are then more easily captured by the
filter system.
Important Notes:
Your ionizer may produce an occasional popping or
cracking sound. This is normal and occurs when a small
buildup of ions is discharged.
After extended use, you may notice dust around the grills
or front panel. This is caused by negative ions exiting the
air outlet, evidence of the ionizer’s air cleaning
effectiveness. You can remove the dust with a soft brush
or clean, damp cloth.
Larger particles may be attracted to positively charged
surfaces throughout the home, like walls or floors.
This may occur more frequently when the filter is
nearing the end of its usable product life and is
unable to capture as many charged particles.
Excessive amounts of pet dander, dust, or smoke may
decrease the life expectancy of the filters and
interfere with the ionization process.
To help prevent particles from attracting to surfaces
throughout your home:
You may want to run the ionizer less often.
Check the condition of filters more frequently.
CAUTION:
The ionizer in this appliance produces less
ozone than the UL established limits of 50ppb. However,
in high concentrations, ozone can be harmful to birds and
small pets. To prevent ozone buildup, we suggest using
the ionizer in well ventilated areas with the fan on.
IMPORTANT:
Always check the condition of the Aer1
®
filters at the recommended intervals and replace filters if
necessary (See FILTER REPLACEMENT INSTRUCTIONS).
Using the ionizer with dirty filters may result in dirty
particles exiting the air cleaner and attracting to walls,
carpets, furniture, or other household objects. These dirty
particles may prove difficult to remove.
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons. These precautions
include:
1.
Read all instructions before using the appliance.
2.
To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
3.
If the filter is covered by a bag when shipped,
remove plastic bag before use.
4.
Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs, near
heat registers, radiators, stoves, or heaters.
5.
To protect against electrical hazards, DO NOT
immerse the appliance in water or other liquids. Do
not use near water.
6.
Close supervision is necessary when any appliance is
used by or near children, or disabled persons.
7.
Always unplug the air purifier before moving or
cleaning the unit, opening the grill, changing the
filters and whenever the unit is not in use. To
disconnect the unit, be sure to pull the plug and not
the cord.
8.
NEVER drop or insert any objects into the openings of
the unit.
9.
DO NOT operate any appliance with a damaged cord
or plug.
10. If the motor fan fails to operate or the unit has been
dropped or damaged in any manner, return
appliance to manufacturer for examination.
11. Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments may cause hazards and is not
recommended or sold by Jarden Consumer Solutions.
12. DO NOT use outdoors.
13. NEVER place on a soft surface such as a bed or sofa
as this could cause the unit to tip over and block the
air inlet or outlet grills.
14. Keep unit away from heated surfaces and open
flames.
15. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty.
16. DO NOT place anything on top of unit.
17. NEVER use detergents, gasoline, glass purifier,
furniture polish, paint thinner, or other household
solvents to clean any part of the appliance.
18. Always turn the appliance off before unplugging it.
19. The ionizer in this appliance produces less ozone than
the UL established limits of 50ppb (parts per billion).
However, in high concentrations, ozone can be
harmful to birds and small pets. To prevent ozone
buildup, we suggest using the ionizer in well
ventilated areas with the fan on.
20. This appliance should only be used in a room with
temperatures between 40° F and 110° F.
21.
WARNING:
To reduce the risk of fire or electric
shock, DO NOT use this appliance with any solid-state
speed control device.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
FEATURES - OPERATIONS
FEATURES - OPERATIONS
CLEANING / MAINTENANCE
OPERATING INSTRUCTIONS
IMPORTANT:
REMOVE ALL PLASTIC BAGS FROM FILTERS BEFORE
USE.
DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.
1.
Plug into a 120V AC electrical outlet.
2.
Press the Power Button (
). The air cleaner will
turn onto HIGH, the High (3) speed button light will
illuminate letting you know the power is on and
running at High setting. To turn the air cleaner off at
any time, press the power button and all button lights
will go off.
3.
You can then select the desired speed setting. This air
cleaner has three speed settings. You can select from
HIGH (3), MEDIUM (2), or LOW (1) by pressing the
desired operating speed control button on the control
panel. The corresponding button light will illuminate
to indicate which setting being selected.
4.
To release negative ions into the filtered air, press the
Ionizer Button (
) and the button light will
illuminate.
5.
This unit has a built in memory function that will
recall the last setting from the previous use. This
memory function will only operate if the unit remains
plugged in between uses.
NOTE:
The ionizer will not work unless the unit is
running.
CLEANING AND MAINTENANCE
Cleaning the unit:
1.
Turn off and unplug the air cleaner.
2.
The outside of the unit can be cleaned with a soft,
clean damp cloth.
3.
The air inlet grill (see figure 1) can be cleaned with a
soft, clean damp cloth.
4.
The filtered air outlet can be cleaned of dust with a
small soft brush.
5.
If you wish to clean the inside of the air cleaner,
please only use a dry, soft cloth to wipe it down. DO
NOT WASH the Aer1
®
filters. The Pre-filter (D) can be
washed by using a mild dish soap and water. Rinse
thoroughly. Allow to air dry completely prior to
reinstalling into the Air Inlet Grill (E).
6.
NEVER use detergents, gasoline, glass cleaner,
furniture polish, paint thinner or other household
solvents to clean any part of the air cleaner.
WARNING:
Do not allow moisture to come in contact
with the main housing of the air cleaner.
FILTER REPLACEMENT INSTRUCTIONS
Every few weeks, check the condition of filters. Filter life
will vary, depending on air quality and usage (see
below). Under normal conditions of continuous use, the
Aer1
®
Total Air, Odor and Smoke Filter will last 4 months
while the Allergen and Allergen PerformancePlus Filter
will last 12 months.
After approximately 12 months of operation, the Filter
Check Indicator Light (
) will illuminate to alert you to
service the filter.
To replace your filter:
1. Turn off and unplug the air
cleaner before attempting
to replace the filters.
2. Remove each of the filters
from the unit by pulling
them gently towards you.
3. Discard the Aer1
®
filters. DO
NOT attempt to clean them.
4. Remove protective plastic
bags and install new Aer1
®
filters into the unit.
NOTE:
Ensure proper
assembly of the filter clip to
the filter. Attach the filter clip
and filter assembly to the air
cleaner hang tabs:
Make sure the hang tab is
securely in place. Align the
clip on the side of the
Aer1
®
filter with the rails
on the inside of the unit. Gently slide the filter onto
the rail (see Figures 2 and 3).
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
Figure 1
C
B
F
G
H
I
D
E
A
A.
Filtered Air Outlet
B.
Control Panel
C.
Aer1
®
Filters
D. Washable Foam
Pre-filter
E.
Air Inlet Grill
F.
Ionizer Button/Light
(
)
G. Filter Reset Button/
Light (
)
H. Speed Control
Buttons/Lights
(1-2-3)
I.
Power Button (
)
CONTROL PANEL (close-up)
Figure 2
Figure 3
CBAP520_12EM1.indd
2
5/15/13
2:17 PM