PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before using the appliance. 2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 3. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers. 4. DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 4 inches away from the wall for best results. 5. NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity). 6. WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord. 7. Never place anything over moisture outlet when the unit is running. 8. NEVER drop or insert any object into any openings. DO NOT place hands, face or body directly over or near Moisture Outlet while unit is in operation. DO NOT cover Moisture Outlet while the unit is operating. 9. DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair. 10. Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold the manufacturer may cause hazards. 11. DO NOT use outdoors. 12. Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture. 13. DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wallpaper. 14. H umidifier should be unplugged when not in use. 15. N EVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. If you have a warm mist humidifier, DO NOT attempt to remove the water tank within 15 minutes after the humidifier is turned off and unplugged. Serious injury may result. 16. This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly cleaning procedures. Use only cleaners and additives recommended by the manufacturer. Never use gasoline, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier. 17. E xcessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF. 18. D o not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local retailer or through the manufacturer, to measure the humidity. 19. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY. FEATURES - OPERATIONS serviceable parts. All servicing should be performed by qualified personnel only. 20. Never place housing under water flow, or immerse in liquids. 21. DO NOT plug in the cord with wet hands, electric shock could result. 22. DO NOT pour water in any openings other than the water tank. 23. If you have a warm mist humidifier, allow unit to cool before refilling water tank or maintenance as the heater bulb is hot. 24. To prevent damage to surfaces, do not place humidifier under overhanging surfaces. 25. NEVER operate unit without water in the tank. 26. Do not move unit after it has been used until unit cools completely. 27. Use both hands when carrying full tank of water. 28. Failure to clean device per the cleaning instructions in the instruction book may result in overheating or fire. CAUTION: Mist can be HOT. Keep away from children. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS CONSUMER SAFETY INFORMATION NOTES: • This is an electrical appliance and requires attention when in use. • If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage. • DO NOT block air inlet or outlet. • Keep unit away from surfaces that can be damaged by water and/or heat (such as wood floors). • Place mat underneath the unit during use. • Do not place the humidifier on carpet. The heat sink underneath the humidifier might cause the carpet to be discolored and may cause overheating of the unit. Cord and Plug Installation Safety Instructions: The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier (refer to the rating information placed on the humidifier). Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over. HOW WARM MIST WORKS Your Holmes® Warm Mist humidifier is designed to allow the proper amount of water to flow out of the tank. Air is drawn in through the grill openings located in the back of the unit and mixed with steam in the misting chamber. The warm mist is then dispersed out of the top of the misting chamber through the outlet grill and into the room. NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%. PRE-OPERATING INSTRUCTIONS 1. Be sure the humidifier is switched off. 2. Select a location for your humidifier, on a flat level surface about 4 inches (10cm) away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture resistant surface. 3. Remove the tank from the main housing. 4. Bring the tank to the sink, turn upside down and twist off the tank cap by turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY. The tank will hold 1 gallon of water. 5. Make sure the safety lock is rotated completely to the locked position. Place tank back on to the housing. The tank will immediately begin to empty into the base. 6. Plug the humidifier into a 120V electrical outlet. MEDICINE TRAY There is a medicine tray located on top of the humidifier. To use, pour designated humidifier medication into the tray and then turn on your humidifier as directed. FEATURES - OPERATIONS NOTES: • DO NOT add medication to the water tank. • DO NOT add medication to the medicine tray when the unit is already operating. overfill the humidifier base. This may cause the humidifier to function intermittently, or stop emitting mist. Should this occurs, simply remove the excess water from the humidifier base. OPERATING INSTRUCTIONS IMPORTANT: 1. To turn on your humidifier, switch the Slider Switch to your desired setting: Off - Hi (High) - Lo (Low) NOTE: This humidifier is featured with rapid steam. After powered on, the humidifier will begin to mist within 1 minute. A boiling noise is normal. To minimize the noise level, operate the unit at low setting. * Visible mist under 1 minute was measured using water at an average temperature of 65°F (18°C). 2. To turn off the unit, switch the Slider Switch to the Off (Off) position. 3. Turn the Humidistat Control to adjust the humidistat level. To begin operation, turn the Humidistat Control to the highest setting ( ). WARNING: DO NOT move the humidifier with water in the tank or the humidifier base. The moving action of the water may activate the water tank's release nozzle and RESET PROCEDURE When the water in the tank is empty and the water in the heating chamber is almost empty, the Automatic Shut Off will activate. The humidifier will stop operation until the water tank is refilled to prevent overheating. Humidifier should be reset as below: 1. Remove and refill the water tank, follow the "Daily Maintenance" and Pre-Operating Instructions to clean and refill the water tank. Replace the tank onto the unit. 2. Allow 15 minutes for the Automatic Shut off to reset. 3. After 15 minutes, press the power button to begin operation of the humidifier. Within 1 minute, the unit will begin to produce moisture. If the unit does not start working, it is still too hot. Wait 15-30 additional minutes for the unit to cool down before pressing the power button to begin operation. The unit should now be cool enough and operate normally. Figure 1 A B C D E Control Panel D B F A. Humidifier Tank B. Humidistat Control C. Medicine Tray D. Slider Switch E. Humidifier Housing F. Humidifier Base CLEANING / MAINTENANCE CLEANING AND MAINTENANCE INSTRUCTIONS The following maintenance procedures must be routinely followed in order to ensure proper, efficient operation of your humidifier. The unit WILL NOT WORK CORRECTLY if it is not cleaned properly. When the unit is in use, daily and weekly maintenance is recommended. Regular weekly cleaning prevents scale buildup on the heating element and tray. It also prevents micro-organisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved. We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and to the avoidance of algae or bacteria build-up. DAILY MAINTENANCE Allow to cool before maintenance. 1. Before cleaning, switch OFF the humidifier and unplug the unit from the electrical outlet. 2. Remove the water tank then unlock the humidifier housing by rotating the safety lock clockwise. Lift housing up from the humidifier base (see Figure 2). Figure 2 Safety Lock on Base UNLOCK Safety Lock Housing Base 3. Empty water and minerals from the base and place in the top rack of the dishwasher. This will remove any sediment and dirt that has accumulated in the base. NOTE: It is imperative that the base is cleaned properly. The base is dishwasher safe (top rack ONLY) for easy cleaning. 4. Wipe the heating element clean with a soft cloth after it has had a chance to cool. 5. Replace misting chamber and engage safety lock. The Electronic Thermal Control Heating element is lined with a coating that is designed to provide the easiest cleaning and prolong the operating efficiency of the humidifier. DO NOT use any metal or hard objects to clean the Heating Element. Never use detergents, gasoline, kerosene, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the humidifier. WEEKLY MAINTENANCE Remove Scale: Allow to cool before maintenance. 1. Repeat steps 1-5 in the Daily Maintenance section. 2. Clean tray, heating element and heating element shroud by filling tray with water solution containing 8-oz of undiluted white vinegar. Allow tray, heating element and heating element shroud to sit in water solution for 20 minutes. Clean tray, heating element and heating element shroud with a soft brush. Dampen a cloth with undiluted white vinegar and wipe out entire tray/base, heating element and heating element shroud area to remove scale. 3. Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank. 4. Wipe the heating element clean with a soft cloth after it has had chance to cool. Disinfect tank: 1. Fill tank with 1/2 teaspoon of chlorine bleach and 1/2 gallon (1.9L) of water. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Dry with a clean cloth or paper towel. 4. Refill the water tank with cool water; replace the water tank. Repeat ALL Operating Instructions.

  • 1
  • 2

PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
FEATURES - OPERATIONS
CLEANING AND MAINTENANCE
INSTRUCTIONS
The following maintenance procedures must be
routinely followed in order to ensure proper,
efficient operation of your humidifier. The unit
WILL NOT WORK CORRECTLY if it is not cleaned
properly.
When the unit is in use, daily and weekly maintenance is
recommended. Regular weekly cleaning prevents scale
buildup on the heating element and tray. It also prevents
micro-organisms from growing on the tray and tank. This
ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper
cleaning is to the maintenance and continued use
of your unit and to the avoidance of algae or
bacteria build-up.
DAILY MAINTENANCE
Allow to cool before maintenance.
1.
Before cleaning, switch OFF the humidifier and
unplug the unit from the electrical outlet.
2.
Remove the water tank then unlock the humidifier
housing by rotating the safety lock clockwise. Lift
housing up from the humidifier base (see Figure 2).
3.
Empty water and minerals from the base and place in
the top rack of the dishwasher. This will remove any
sediment and dirt that has accumulated in the base.
NOTE:
It is imperative that the base is cleaned properly.
The base is dishwasher safe (top rack ONLY) for easy cleaning.
4.
Wipe the heating element clean with a soft cloth after
it has had a chance to cool.
5.
Replace misting chamber and engage safety lock. The
Electronic Thermal Control Heating element is lined
with a coating that is designed to provide the easiest
cleaning and prolong the operating efficiency of the
humidifier. DO NOT use any metal or hard objects to
clean the Heating Element. Never use detergents,
gasoline, kerosene, glass cleaner, furniture polish,
paint thinner or other household solvents to clean
any part of the humidifier.
WEEKLY MAINTENANCE
Remove Scale:
Allow to cool before maintenance.
1.
Repeat steps 1-5 in the Daily Maintenance section.
2.
Clean tray, heating element and heating element
shroud by filling tray with water solution containing
8-oz of undiluted white vinegar. Allow tray, heating
element and heating element shroud to sit in water
solution for 20 minutes. Clean tray, heating element
and heating element shroud with a soft brush.
Dampen a cloth with undiluted white vinegar and
wipe out entire tray/base, heating element and
heating element shroud area to remove scale.
3.
Rinse with clean warm water to remove scale and the
white vinegar solution before beginning to disinfect
the tank.
4.
Wipe the heating element clean with a soft cloth after
it has had chance to cool.
Disinfect tank:
1.
Fill tank with 1/2 teaspoon of chlorine bleach and
1/2 gallon (1.9L) of water.
2.
Let the solution stand for 20 minutes, swishing every
few minutes. Wet all surfaces.
3.
Empty the tank after 20 minutes, and rinse well with
water until the bleach smell is gone. Dry with a clean
cloth or paper towel.
4.
Refill the water tank with cool water; replace the
water tank. Repeat ALL Operating Instructions.
serviceable parts. All servicing should be performed
by qualified personnel only.
20.
Never place housing under water flow, or immerse in
liquids.
21.
DO NOT plug in the cord with wet hands, electric
shock could result.
22.
DO NOT pour water in any openings other than the
water tank.
23.
If you have a warm mist humidifier, allow unit to cool
before refilling water tank or maintenance as the
heater bulb is hot.
24.
To prevent damage to surfaces, do not place
humidifier under overhanging surfaces.
25. NEVER operate unit without water in the tank.
26.
Do not move unit after it has been used until unit
cools completely.
27.
Use both hands when carrying full tank of water.
28. Failure to clean device per the cleaning instructions in
the instruction book may result in overheating or fire.
CAUTION:
Mist can be HOT. Keep away
from children
.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
CONSUMER SAFETY INFORMATION
NOTES:
This is an electrical appliance and requires attention
when in use.
If moisture forms on the walls or windows of the room,
turn off the humidifier. The room already has plenty of
humidity and additional moisture may cause damage.
DO NOT block air inlet or outlet.
Keep unit away from surfaces that can be damaged by
water and/or heat (such as wood floors).
Place mat underneath the unit during use.
Do not place the humidifier on carpet. The heat sink
underneath the humidifier might cause the carpet to be
discolored and may cause overheating of the unit.
Cord and Plug Installation Safety Instructions:
The length of cord used on this appliance was selected to
reduce the hazards of becoming tangled in, or tripping
over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical
rating of the extension cord must be equal to or greater
than the rating of the humidifier (refer to the rating
information placed on the humidifier). Care must be
taken to arrange the extension cord so that it will not
drape over the countertop or tabletop where it can be
pulled on by children or accidentally tripped over.
HOW WARM MIST WORKS
Your Holmes
®
Warm Mist humidifier is designed to allow
the proper amount of water to flow out of the tank. Air is
drawn in through the grill openings located in the back of
the unit and mixed with steam in the misting chamber.
The warm mist is then dispersed out of the top of the
misting chamber through the outlet grill and into the
room.
NOTE:
A humidity level below 20% can be unhealthy
and uncomfortable. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1.
Be sure the humidifier is switched off.
2.
Select a location for your humidifier, on a flat level
surface about 4 inches (10cm) away from the wall.
DO NOT place the humidifier on a finished floor or
near furniture, which can be damaged by too much
moisture or water. Place on a moisture resistant surface.
3.
Remove the tank from the main housing.
4.
Bring the tank to the sink, turn upside down and
twist off the tank cap by turning counter clockwise.
Fill tank with cool, fresh tap water. DO NOT fill with
warm water as this may cause leaking. Replace the
cap on tank FIRMLY. The tank will hold 1 gallon of water.
5.
Make sure the safety lock is rotated completely to the
locked position. Place tank back on to the housing.
The tank will immediately begin to empty into the base.
6.
Plug the humidifier into a 120V electrical outlet.
MEDICINE TRAY
There is a medicine tray located on top of the humidifier. To
use, pour designated humidifier medication into the tray and
then turn on your humidifier as directed.
FEATURES - OPERATIONS
CLEANING / MAINTENANCE
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1.
Read all instructions before using the appliance.
2.
To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
3.
Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs or near
heat registers.
4.
DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. DO locate your
humidifier on an inside wall near an electrical outlet.
The humidifier should be at least 4 inches away from
the wall for best results.
5.
NEVER place humidifier in an area where it is
accessible to children. NEVER use humidifier in a
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6.
WARNING:
Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury. Be sure to unplug the unit by pulling
on the plug and not the cord.
7.
Never place anything over moisture outlet when the
unit is running.
8.
NEVER drop or insert any object into any openings.
DO NOT place hands, face or body directly over or
near Moisture Outlet while unit is in operation. DO
NOT cover Moisture Outlet while the unit is operating.
9.
DO NOT operate any appliance with a damaged cord
or plug, after the appliance malfunctions, or if it has
been dropped or damaged in any manner. Return
appliance to manufacturer for examination, electrical
or mechanical adjustment, or repair.
10.
Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold the
manufacturer may cause hazards.
11.
DO NOT use outdoors.
12.
Always place humidifier on a firm, flat, level surface.
A waterproof mat or pad is recommended for use
under the humidifier. NEVER place it on a rug or
carpet, or on a finished floor that may be damaged
by exposure to water or moisture.
13.
DO NOT allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wallpaper.
14.
Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit. If you have a warm
mist humidifier, DO NOT attempt to remove the water
tank within 15 minutes after the humidifier is turned
off and unplugged. Serious injury may result.
16.
This humidifier requires daily and weekly
maintenance to operate appropriately. Refer to daily
and weekly cleaning procedures. Use only cleaners
and additives recommended by the manufacturer.
Never use gasoline, glass cleaner, furniture polish,
paint thinner, or other household solvents to clean
any part of the humidifier.
17.
Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
18.
Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer,
available at your local retailer or through the
manufacturer, to measure the humidity.
19.
DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
NOTES:
DO NOT add medication to the water tank.
DO NOT add medication to the medicine tray when the
unit is already operating.
OPERATING INSTRUCTIONS
IMPORTANT:
1. To turn on your humidifier, switch the Slider Switch to
your desired setting:
Off - Hi (High) - Lo (Low)
NOTE:
This humidifier is featured with rapid steam.
After powered on, the humidifier will begin to mist
within 1 minute. A boiling noise is normal. To minimize
the noise level, operate the unit at low setting.
* Visible mist under 1 minute was measured
using water at an average temperature of
65°F (18°C)
.
2.
To turn off the unit, switch the Slider Switch to the Off
(
Off
) position.
3.
Turn the Humidistat Control to adjust the humidistat
level. To begin operation, turn the Humidistat Control
to the highest setting (
).
WARNING:
DO NOT move the humidifier with water in
the tank or the humidifier base. The moving action of the
water may activate the water tank’s release nozzle and
overfill the humidifier base. This may cause the
humidifier to function intermittently, or stop emitting
mist. Should this occurs, simply remove the excess water
from the humidifier base.
RESET PROCEDURE
When the water in the tank is empty and the water in the
heating chamber is almost empty, the Automatic Shut Off
will activate. The humidifier will stop operation until the
water tank is refilled to prevent overheating. Humidifier
should be reset as below:
1. Remove and refill the water tank, follow the "Daily
Maintenance" and Pre-Operating Instructions to clean
and refill the water tank. Replace the tank onto the
unit.
2. Allow 15 minutes for the Automatic Shut off to reset.
3. After 15 minutes, press the power button to begin
operation of the humidifier. Within 1 minute, the unit
will begin to produce moisture. If the unit does not
start working, it is still too hot. Wait 15-30 additional
minutes for the unit to cool down before pressing the
power button to begin operation. The unit should now
be cool enough and operate normally.
D
Figure 1
A. Humidifier Tank
B. Humidistat Control
C. Medicine Tray
D. Slider Switch
E. Humidifier Housing
F. Humidifier Base
Control Panel
B
F
A
B
D
C
E
Housing
Figure 2
Safety Lock on Base
Safety Lock
Base
UNLOCK