Honeywell 4219 Installation Guide - Page 2
See The Control Panel's Installation And Setup Guide For Complete Information, Regarding - addressing a
UPC - 781410000872
View all Honeywell 4219 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
DIP SWITCH FOR SETTING ADDRESS AND ZONE A RESPONSE 4219 NOTE FOR CE INSTALLATIONS A N6361EMI SUPPRESSION BEAD IS REQUIRED. REED (TAMPER) SWITCH TAMPER JUMPER POSITION 4219 IN CABINET (NOT TAMPER) 4219 REMOTE (TAMPER PROTECTED) 4-PIN CONSOLE PLUG CONNECTIONS SAME AS TB2 TB1 1 2 3 4 5 6 7 8 9 10 11 12 TB2 4 3 4 3 22 11 GRN DATA OUT TO CONTROL BLK (-) GROUND RED (+) 12VDC YEL DATA IN FROM CONTROL ZONES A B CD EF GH Figure 2. Summary of Connections TERMINATE EACH PROGRAMMED ZONE WITH 1000 OHM END-OF-LINE RESISTOR (EACH ZONE'S MAX. LOOP RESISTANCE: 300 OHMS + EOL) 4219-SOC-V0 © 12 3 4 5 OFF ON © © © © SWITCH NUMBER 4219 ADDRESS SETTINGS ("-"means"OFF") 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 ON - ON - ON - ON - ON - ON - ON - ON - 3 ON ON - - ON ON - - ON ON - - ON ON - - 4 ON ON ON ON - - - - ON ON ON ON - - - - 5 ON ON ON ON ON ON ON ON DIP SWITCH: (WHITE AREAS DENOTE SWITCH HANDLES) POSITIONS 2-5: DETERMINE ZONE EXPANDER'S ADDRESS. CONSULT CONTROL'S INSTRUCTIONS FOR ADDRESS USE. SWITCH SETTING SHOWN SET FOR ADDRESS "0". POSITION 1: DETERMINES ZONE A's RESPONSE TIME: ON = NORMAL (300MS) RESPONSE, SHOWN (AS SHIPPED). OFF = FAST (10MS) RESPONSE TO AN OPEN. 4219-001-V0 Figure 3. DIP Switch Settings SEE THE CONTROL PANEL'S INSTALLATION AND SETUP GUIDE FOR COMPLETE INFORMATION REGARDING THE LIMITATIONS OF THE ENTIRE SECURITY SYSTEM.