Honeywell 6160CR-2 Setup Guide - Page 2
ÊK3590-2CF2Š - red fire keypad
View all Honeywell 6160CR-2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
BLACK RED Y+ G Set the desired address: Enter the desired address. For example, for address 12, enter 1, then 2. Display shows (12). 2. Exit the address mode: Press the "star" key (✻) to save the displayed address and exit the address mode. The current address may be viewed at any time by pressing and holding [1] and [3] keys together. + + + + + + + + 6160CR-004-V1 Figure 2 - 6160CR-2 Wiring Details SETTING THE KEYPAD ADDRESS The keypad address must be set according to the control panel being used (refer to the individual control panel's instructions for details). Available addresses are from 00 through 30. The keypad is shipped with a default address of 31 (non-addressable mode). To change the address, do the following: 1. Enter keypad address mode: Power up the keypad. Within 60 seconds of power-up, press and hold down the [1] and [3] keys together for 3seconds. The current address will be displayed and the cursor will be under the "tens" digit (31). Notes: • If the system has been powered up for more than 60 seconds, you must power the keypad down, and then power it up again in order to change the keypad's address. • The keypad will not enter the address mode if the system is in the program mode. • If 10 seconds have passed with no key entry, the keypad automatically exits the address mode. KEYPAD LABELS Function key labels: A set of adhesive-backed labels with some typical function symbols (e.g., police, emergency, etc.) is provided. These labels come in four colors (red, blue, green, and white) and may be placed on the appropriate function keys (A, B, or C) for ease of identifying the individual key's function (as determined by the control panel's capability and programming). OPERATING THE KEYPAD For operating instructions, see the User Guide for the control panel with which this keypad is used. SPECIFICATIONS Physical: 5.25" H x 7.437" W x 1.312" D Display: Alphanumeric, 32-character (2 lines x 16 characters), LCD back-lit Sounder: Electrical: High-quality speaker Voltage: +12VDC (from power-limited source) Current: 45mA standby; 160mA in alarm (sounder, back light and LEDs on) NFPA-72 Compliant FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE SYSTEM, REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED. ÊK3590-2CF2Š K3590-2CF 9/08 Rev. B 2 Corporate Center Drive, Suite 100 P.O. Box 9040 Melville, NY 11747 Copyright © 2007 Honeywell International Inc. www.security.honeywell.com