Honeywell DH65DG115 User Guide - Page 7

Main Return to Main Return, Dedicated Return to Main Return, Main Return to Main Supply, Dedicated

Page 7 highlights

TrueDRY DH65 Install to Fit Your Application Flex duct is recommended in connecting to the TrueDRY DH65 collars to reduce vibration noise. Duct Sizing: Use minimum 8-in. diameter round for duct lengths up to 25 ft. Minimum 10-in. required for lengths longer than 25 ft. Duct branches from the main inlet/exhaust should be minimum 8-in. round for 2-3 branches, and 8-in. round or larger for 4 branches or more. Isolated Areas: Effective dehumidification may require ducting to isolated or stagnant air flow areas. M27405 WARNING: Exposed internal fan may cause injury. Ducting of the exhaust port is required. Electrical requirements: 115VAC outlet. Ground fault interrupter (GFI) recommended. Main Return to Main Return A AIR HANDLER RETURN SUPPLY Ideal when... M24745 • Running TrueDRY DH65 with A/C operation. • Minimizing discharge air temperature (DAT) increase is preferred. • Space dictates. TrueDRY M27325 Main Return to Main Supply B RETURN AIR HANDLER SUPPLY Ideal when... • Running TrueDRY DH65 opposite A/C operation. Running with A/C operation requires damper on the exhaust port to minimize backdraft when TrueDRY DH65 is not on but A/C is. BACKDRAFT TrueDRY DAMPER M27324 Dedicated Return to Main Supply • Minimizing DAT increase is preferred. • Space dictates. C RETURN AIR HANDLER SUPPLY Ideal when... • Drying a specific area of the house. SEPERATE RETURN BACKDRAFT TrueDRY DAMPER M27326 Dedicated Return to Main Return D RETURN AIR HANDLER SUPPLY • Running with A/C operation requires backdraft damper on the exhaust port to minimize backdraft when TrueDRY DH65 is not on but A/C is. • Minimizing DAT increase is preferred. Ideal when... • Drying a specific conditioned or unconditioned area, such as attic, basement, or crawl space. • Running with A/C operation. • Minimizing DAT is preferred. SEPERATE RETURN TrueDRY M27601 5 69-2089EFS-08 69-2089EFS_D.indd 5 9/22/2008 10:02:34 AM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

TrueDRY DH65
5
69-2089EFS—08
Flex duct is recommended in connecting to the TrueDRY DH65 collars to reduce vibration noise.
M24745
Electrical requirements:
115VAC outlet. Ground fault
interrupter (GFI) recommended.
Duct Sizing:
Use minimum 8-in. diameter round for duct
lengths up to 25 ft. Minimum 10-in. required for lengths longer
than 25 ft. Duct branches from the main inlet/exhaust should
be minimum 8-in. round for 2-3 branches, and 8-in. round or
larger for 4 branches or more.
Isolated Areas:
Effective dehumidification may require duct
-
ing to isolated or stagnant air flow areas.
Install to Fit Your Application
M27405
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27325
A
Main Return to Main Return
SUPPLY
RETURN
AIR HANDLER
M27601
TrueDRY
SEPERATE
RETURN
D
Dedicated Return to Main Return
Ideal when…
Running TrueDRY DH65 with A/C operation.
Minimizing discharge air temperature (DAT)
increase is preferred.
Space dictates.
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27324
BACKDRAFT
DAMPER
B
Main Return to Main Supply
Ideal when…
Running TrueDRY DH65 opposite A/C
operation. Running with A/C operation requires
damper on the exhaust port to minimize
backdraft when TrueDRY DH65 is not on but
A/C is.
Minimizing DAT increase is preferred.
Space dictates.
Ideal when…
Drying a specific area of the house.
Running with A/C operation requires backdraft
damper on the exhaust port to minimize
backdraft when TrueDRY DH65 is not on but
A/C is.
Minimizing DAT increase is preferred.
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27326
SEPERATE
RETURN
BACKDRAFT
DAMPER
C
Dedicated Return to Main Supply
Ideal when…
Drying a specific conditioned or unconditioned
area, such as attic, basement, or crawl space.
Running with A/C operation.
Minimizing DAT is preferred.
WARNING:
Exposed internal fan may cause injury.
Ducting of the exhaust port is required.
69-2089EFS_D.indd
5
9/22/2008
10:02:34 AM