Honeywell HEGS5300 User Manual - Page 12
Wiring Connections, Cable Lengths
View all Honeywell HEGS5300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
2.4 WIRING CONNECTIONS RJ11 Socket on rear of keyboard Pin 1 - Power GND Pin 2 - TX Data Pin 3 - Signal GND Pin 4 - RX Data Pin 5 - N/C Pin 6 - 12Vdc RJ11 Socket on Keyboard RJ11 Socket on rear of HMXAT200 Pin 6 - Power GND Pin 5 - RX Data Pin 4 - Signal GND Pin 3 - TX Data Pin 2 - N/C Pin 1 - 12Vdc RJ Leads for Connecting Keyboards Pin 6 Pin 1 2.5 CABLE LENGTHS Refer to the following illustrations for examples of wiring connections. NOTE: The HEGS5300 CCTV Keyboard is supplied with a standard 7-foot flat telephone cable. It is strongly recommended that twisted-pair data cable is used from the RJ11 Termination Box when long cable lengths are required to eliminate any data problems. Any cable length in excess of RS232 standards (50 feet) requires line driver units (model number PTE102). Example 1 7-FOOT FLAT TELEPHONE CABLE (PROVIDED WITH HEGS5300) HEGS5300 KEYBOARD HMXAT200 SYSTEM CONTROLLER Rev. A POWER PROVIDED FOR CONTROLLER ON PORTS 3 & 4 NOTE: ONLY PORT 4 ON MINIMAX UNITS 6 MXMU000933 07/07/04