MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PREFILTER The stage 1 particle pre-filter helps pick up large airborne Fig. 9 particles that enter the rear grille. This pre-filter can be periodically removed and shaken to clean it. Alternatively, it can be rinsed by hand under warm water (Fig. 9). Let the pre-filter air dry completely before inserting back into the unit (Fig. 10). If you need to replace this item, please call 1-800-477-0457 or visit www.kaz.com. OPTIONAL: Changing the Odor Control Filter Fig.10 II If you have chosen to use the CZ odor control filter that came with your air purifier, it will lose its effectiveness over time and will need to be replaced. Call 1-800-477-0457 or visit www.kaz.com to order your replacement odor control filters. If using the CZ odor control filter, it is recommended that you store the original washable pre-filter in the event that you decided to use it in the future. To insert it into the unit, simply place securely into the rear grille in lieu of standard pre-filter as shown in figure 10. Note: The CZ filter is not washable. REPLACING THE ULTRAVIOLET (UV) BULBS • After about six months of continuous use, the UV bulbs must be replaced. • When it is time to replace the bulbs, the UV Bulb indicator light (Fig. 11) will change from green to red and the display will show this message. • To replace the bulb cartridge take the following steps: Fig. 11 • /. REPLACE UVDab Z PRESS AND HOW RESET OMR, 1 I EN FILTER S-- Us LIMY Fig. 12 • Be sure to turn off and unplug your air purifier. Fig. 13 • Remove the rear grille and the upper HEPA Type filter (Fig. 12). • Remove the UV bulb by pulling it from the unit (Fig. 13). Dispose old 11V Bulb cartridge only at household hazardous waste collection sites. ▪ Insert a new UV bulb (HUV-145). Make sure it is completely inserted into the main unit. ▪ Replace the HEPA Type filter and rear grille. • Plug the air purifier back into an electrical socket and turn the air purifier on. • Press and hold the UV Bulb button for 5 seconds or until the light turns from red to green and the UV bulb related message in the display is cleared (Fig. 14) . Fig. 14 rER RES REPLACE UV OMB PRESS AND ROW RESET • Notes: Bulb cartridge is not intended for use with any other product or purpose. This unit is equipped with a safety interlock switch. The unit will not operate while the rear grille is removed.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

MAINTAINING
YOUR
STAGE
1
WASHABLE
PARTICLE
PREFILTER
The
stage
1
particle
pre
-filter
helps
pick
up
large
airborne
particles
that
enter
the
rear
grille.
This
pre
-filter
can
be
periodically
removed
and
shaken
to
clean
it.
Alternatively,
it
can
be
rinsed
by
hand
under
warm
water
(Fig.
9).
Let
the
pre
-filter
air
dry
completely
before
inserting
back
into
the
unit
(Fig.
10).
If
you
need
to
replace
this
item,
please
call
1-800-477-0457
or
visit
www.kaz.com.
Fig.
9
OPTIONAL:
Changing
the
Odor
Control
Filter
If
you
have
chosen
to
use
the
CZ
odor
control
filter
that
came
with
your
air
purifier,
it
will
lose
its
effectiveness
over
time
and
will
need
to
be
replaced.
Call
1-800-477-0457
or
visit
www.kaz.com
to
order
your
replacement
odor
control
filters.
If
using
the
CZ
odor
control
filter,
it
is
recommended
that
you
store
the
original
washable
pre
-filter
in
the
event
that
you
decided
to
use
it
in
the
future.
To
insert
it
into
the
unit,
simply
place
securely
into
the
rear
grille
in
lieu
of
standard
pre
-filter
as
shown
in
figure
10.
Note:
The
CZ
filter
is
not
washable.
Fig.10
II
REPLACING
THE
ULTRAVIOLET
(UV)
BULBS
After
about
six
months
of
continuous
use,
the
UV
bulbs
must
be
replaced.
When
it
is
time
to
replace
the
bulbs,
the
UV
Bulb
indicator
light
(Fig.
11)
will
change
from
green
to
red
and
the
display
will
show
this
message.
To
replace
the
bulb
cartridge
take the
following
steps:
Be
sure
to
turn
off
and
unplug
your
air
purifier.
Fig.
13
Remove
the
rear
grille
and
the
upper
HEPA
Type
filter
(Fig.
12).
Remove
the
UV
bulb
by
pulling
it
from
the
unit
(Fig.
13).
Dispose
old
11V
Bulb
cartridge
only
at
household
hazardous
waste
collection
sites.
Insert
a
new
UV
bulb
(HUV-145).
Make
sure
it
is
completely
inserted
into
the
main
unit.
Replace
the
HEPA
Type
filter
and
rear
grille.
Plug
the
air
purifier
back
into
an
electrical
socket
and
turn
the
air
purifier
on.
Press
and
hold
the
UV
Bulb
button
for
5
seconds
or
until
the
light
turns
from
red
to
green
and
the
UV
bulb
related
message
in
the
display
is
cleared
(Fig.
14)
.
Notes:
Bulb
cartridge
is
not
intended
for
use
with
any
other
product
or
purpose.
This
unit
is
equipped
with
a
safety
interlock
switch.
The
unit
will
not
operate
while
the
rear
grille
is
removed.
Fig.
11
/.
REPLACE
UV
Dab
Z
PRESS
AND
HOW
RESET
OMR,
1
I
EN
FILTER
S
--
Us
LIMY
Fig.
12
Fig.
14
rER
RES
REPLACE
UV
OMB
PRESS
AND
ROW
RESET