Cleaning and maintenance
UPC - 085267310635
View all Honeywell HM512DG115 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Operating Manual Cleaning and maintenance Maintenance is made simple with the TrueSTEAM-just remove the water tank for cleaning. Warning: Scalding hazard. Do not attempt to remove the humidifier from the mounting bracket during operation, or the humidifier's water tank when full of water. The heating element could be hot when tank is removed. Failure to comply could result in severe scalding or death. CAUTION Hot water temperature above 140°F (60°C) can cause burns from scalding. Drain Operation • Auto flushing is configurable to 10, 20 or 30 hours of operational time (heating element active). • During auto flushing, cold water will enter the tank to lower water temperature below 140°F (60°C) before draining. • During manual flush (performed by pressing the EMPTY button) initial water temperature may be above 140°F (60°C). Ensure drain outlet is not exposed and use caution when pressing the EMPTY button, and do NOT attempt to remove the tank with water in it. • Manual flush takes approximately 15 minutes to empty the tank completely. To clean TrueSTEAM: 1. Press the EMPTY button. Wait for the CLEAN TANK light to be on solid (not blinking). Wait (approximately 15 minutes) Go to Step 2 EMPTY CLEAN TANK (BLINKING LIGHT) CLEAN TANK (ON SOLID) M24774 M24775 M24776 69-2035EFS-05