Honeywell HP300ULM Installation Instructions - Page 2
Installation Instructions, Mounting, Power Supply Input Connection, Warranty, Output Connections
View all Honeywell HP300ULM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
- Each PTC protected output rated 2.5A @ 23C with a maximum of 2.0A @ 49C. - Automatic Yellow LED status indication of activated PTC. - Test push button lights Yellow LED's to verify their operation. - Red LED for power on indication. • Fire Alarm Control Panel Input - Polarity reversing input. - Normally open (NO) or normally closed (NC) supervised input with 2.2K Ohm (EOL) resistor. - Engineering Reset (Optional) normally open (NO) or normally closed (NC) input with 2.2 K Ohm (EOL) resistor. • Alarm Outputs - Alarm outputs are Fail Safe - When FACP activation occurs dry contacts activated. - Green LED indication when FACP is activated. - Dry contacts output for power failure to the HPMOM5. • Board Dimensions: 5.3" L x 3.5" W x 1.0" H (13.46 cm L x 8.89 cm W x 2.54 cm H). 3 Installation Instructions 1. Mounting The power supply should be installed in accordance with all Governing National Electrical and Local Codes. Mount the power supply securely in the desired location using the four (4) mounting holes. 2. Power Supply Input Connection Before connecting power review the entire wiring diagram for correct installation (see Fig. 1). With the AC power disconnected, connect 120VAC to the Fuse Block as follows; L=Black (HOT), N=WHITE (Neutral), G=GREEN (Ground). Select the output voltage 12VDC or 24VDC using Jumper J1 of the Power Board J1 OFF=12VDC, J1 ON=24VDC. Voltage is Factory set and Re-Adjusting will void Warranty. 3. Output Connections There are 6 outputs selectable together as Switched Normally Open (NO) or Switched Normally Closed (NC). There are 2 possible output type connections in either case connect device negative to Neg terminal on HPMOM5. 1.) For Fail Safe operation connect device positive to DC STANDBY OUTPUT (+) on HPMOM6. DC power is present in normal condition and will switch OFF when the FACP is triggered. Fail Safe operation devices such as Magnetic Locks should be connected to this output. 2.) For Fail Secure operation connect device positive to DC ALARM OUTPUT (+) on HPMOM6. DC power is not present in normal condition and will switch ON when the FACP is triggered. Fail Secure operation devices such as Door Strikes should be connected to this output. 4. Fire Alarm Interface Normally Open (NO), Normally Closed (NC) input or polarity reversal (Rev. Volt) input from the FACP are available to trigger the HPMOM6 operation. Connect the positive (+) and negative (-) from the FACP to the "REV. VOLT" terminals observing polarity, (polarity is referenced in alarm condition) or connect the NO or NC from the FACP output to the "FIRE INTRFC" terminals. Install the 2.2K Ohm (EOL) resistor provided at the FACP as shown in Fig 1 to supervise this connection. 5. Engineering Reset Input This option is available when the jumper JL is removed. This will cause the HPMOM6 to latch upon receiving an alarm condition from the FACP. With this option in place and when the FACP resets, the unit will only reset by activating the "RESET" circuit. a.) JL ON will cause the unit to follow the status of the FACP. Connect 2.2K Ohm resistor to the "RESET" terminals. Continued on next page... 2 HP300ULMCB Installation Document P/N 52387:A 12/29/05