Honeywell T8001 Owner's Manual - Page 15

Minimum Off-Timing - thermostat no power

Page 15 highlights

Minimum Off-Timing The thermostat minimum off-timer assures that the compressor does not come on again for at least five minutes after it turns off. The minimum off-timer is triggered when the compressor turns off and when the SYSTEM switch position is changed. If the compressor turns off when the setpoint is changed, the minimum off-timer is triggered. Power interruption and power restoration also trigger the minimum off-timer. The minimum off-timer operates in cooling on the T8000 and T8001, T8002, T8024 (multistage model) and in first stage heating or cooling on the T8011 (heat pump model). A flashing flame or snowflake indicates the minimum off-time is in effect. 15 69-1431-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

15
69-1431–1
The minimum off-timer operates in cooling on
the T8000 and T8001, T8002, T8024 (multi-
stage model) and in first stage heating or
cooling on the T8011 (heat pump model). A
flashing flame
or snowflake
indicates the
minimum off-time is in effect.
Minimum Off-Timing
The thermostat minimum off-timer assures that
the compressor does not come on again for at
least five minutes after it turns off. The minimum
off-timer is triggered when the compressor turns
off and when the SYSTEM switch position is
changed. If the compressor turns off when the
setpoint is changed, the minimum off-timer is
triggered. Power interruption and power
restoration also trigger the minimum off-timer.