Honeywell T812A1002 User Guide - Page 4

T8131a,b,c; T8132a,b,c, Installation - security

Page 4 highlights

T8131A,B,C; T8132A,B,C INSTALLATION Fig. 3-Mounting thermostat mounting plate. WALL ANCHORS (2) WALL WIRES THROUGH WALL OPENING MOUNTING PLATE MOUNTING SCREWS (2) M1718 WIRING All wiring must comply with all applicable electrical codes, ordinances, and regulations. Follow instructions provided with the controlled equipment. Loosen the terminal screws and slip each wire beneath its matching terminal. See Fig. 4 for wiring insertion techniques. Tighten terminals securely. Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation. T8131 Models Run the required number of wires to the thermostat location (check the appropriate wiring diagram). Refer to Figs. 5 through 7 for typical wiring diagrams. T8132 Models Run the required number of wires to the thermostat location (check the appropriate wiring diagram). Refer to Figs. 8 through 11 for typical wiring diagrams. In 5-wire installations only, be sure to remove the factory-installed jumper connecting terminals R and Rc. Fig. 4-Proper wiring technique. PROPER WIRING TECHNIQUE 5/16 in. [8 mm] STRIP INSERT STRAIGHT UNDER SCREW HEAD END OF WIRE VISIBLE HERE M3825 Fig. 5-3-wire heat-only application. 3-WIRE HEAT-ONLY A B W Y G C R HEATING RELAY OR VALVE COIL 1 L1 (HOT) L2 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M9213 Fig. 6-4-wire cool-only application. 4-WIRE COOL-ONLY A B W Y G C R COOLING CONTACTOR COIL FAN RELAY 1 L1 (HOT) L2 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M9212 Fig. 7-5-wire heat/cool application. 5-WIRE HEAT/COOL A B W Y G C R HEATING RELAY OR VALVE COIL FAN RELAY COOLING CONTACTOR COIL 1 L1 (HOT) L2 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M9214 68-0148-1 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

68-0148—1
4
Fig. 3—Mounting thermostat mounting plate.
T8131A,B,C; T8132A,B,C
INSTALLATION
WALL
WIRES THROUGH
WALL OPENING
WALL
ANCHORS (2)
MOUNTING
PLATE
MOUNTING
SCREWS (2)
M1718
WIRING
All wiring must comply with all applicable electrical
codes, ordinances, and regulations. Follow instructions
provided with the controlled equipment.
Loosen the terminal screws and slip each wire beneath
its matching terminal. See Fig. 4 for wiring insertion tech-
niques. Tighten terminals securely.
Plug the hole in the wall with insulation to help prevent
drafts from adversely affecting thermostat operation.
T8131 Models
Run the required number of wires to the thermostat
location (check the appropriate wiring diagram). Refer to
Figs. 5 through 7 for typical wiring diagrams.
T8132 Models
Run the required number of wires to the thermostat
location (check the appropriate wiring diagram). Refer to
Figs. 8 through 11 for typical wiring diagrams.
In 5-wire installations only, be sure to remove the fac-
tory-installed jumper connecting terminals R and Rc.
Fig. 4—Proper wiring technique.
Fig. 5—3-wire heat-only application.
Fig. 7—5-wire heat/cool application.
Fig. 6—4-wire cool-only application.
C
R
W
Y
G
B
A
3-WIRE HEAT-ONLY
M9213
POWER SUPPLY.
PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
1
1
L1
(HOT)
L2
HEATING
RELAY OR
VALVE COIL
C
R
W
Y
G
B
A
4-WIRE COOL-ONLY
L1
(HOT)
L2
POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
1
M9212
COOLING
CONTACTOR
COIL
FAN
RELAY
C
R
W
Y
G
B
A
5-WIRE HEAT/COOL
L1
(HOT)
L2
POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
1
HEATING
RELAY OR
VALVE COIL
M9214
COOLING
CONTACTOR
COIL
FAN
RELAY
M3825
INSERT
STRAIGHT
UNDER
SCREW HEAD
5/16 in.
[8 mm]
STRIP
END OF WIRE
VISIBLE HERE
PROPER WIRING TECHNIQUE