English: Page 1 • Français : Page 6 • Español: Página 11 Base installation 1. Pull wires through wire hole. Position base on wall, level and mark hole positions. 2. Drill holes (3/16" holes for drywall, 7/32" holes for plaster), then tap in supplied wall anchors. 3. Pull wires through base, position over anchors, and insert screws. Check level if desired, then tighten screws. Wiring 1. Loosen screw terminals, insert bare wires beneath screws, then re-tighten screws. 2. Push any excess wire back into the wall opening 3. Plug the wall opening with nonflammable insulation to prevent drafts from affecting thermostat operation. Terminal Designations R Heating power. Connect to secondary side of heating system transformer. W1 Heat relay. Y2 Cool relay, or normally open hot water valve. G Fan relay (select models only) 1 T822K and T827K 2 T822L Wire specifications Use 18-gauge thermostat wire. Shielded cable is not required. M27305 M27306 3 69-2251EFS-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

English: Page 1 • Français : Page 6 • Español: Página 11
3
69-2251EFS—01
M27305
M27306
1.
Pull wires through wire hole.
Position base on wall, level and
mark hole positions.
2.
Drill holes (3/16” holes for
drywall, 7/32” holes for plas-
ter), then tap in supplied wall
anchors.
3.
Pull wires through base, posi-
tion over anchors, and insert
screws. Check level if desired,
then tighten screws.
Base installation
1.
Loosen screw terminals, insert bare wires
beneath screws, then re-tighten screws.
2.
Push any excess wire back into the wall
opening
3.
Plug the wall opening with nonflammable
insulation to prevent drafts from affecting
thermostat operation.
Terminal Designations
R
Heating power. Connect to secondary
side of heating system transformer.
W
1
Heat relay.
Y
2
Cool relay, or
normally open hot water valve.
G
Fan relay (select models only)
1
T822K and T827K
2
T822L
Wire specifications
Use 18-gauge thermostat wire. Shielded
cable is not required.
Wiring