Honeywell TH9421 Owner's Manual - Page 27
Humidifier pad change reminder, UV lamp change reminder, Adaptive Intelligent Recovery
View all Honeywell TH9421 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Advanced functions VisionPRO® IAQ Humidifier pad change reminder Function 0510 This feature displays an alert to remind you to change the humidifier pad. Press s/t to set the desired interval: Options: 0 Off (no reminder to change humidifier pad) 1 30-day run time, 90 calendar days ** 2 60-day run time, 180 calendar days ** 3 90-day run time, 365 calendar days ** E Auto Alert (requires optional equipment) Note: Press RESET to cancel the alert **interval depends on humidifier UV lamp change reminder Function 0520 This feature displays an alert to remind you to change the ultraviolet lamp. Press s/t to set the desired interval: Options: 0 Off (no reminder to change UV lamp) 1 Reminder after 1 year 2 Reminder after 2 years E Auto Alert (requires optional equipment) Note: Press RESET to cancel the alert Adaptive Intelligent Recovery Function 0530 Press s/t to turn this feature on or off (see page 13): Options: 0 Off 1 On 25 69-1815EFS-06