What to buy When purchasing a new agitator brush roll, ask for HOOVER part no. 48414140. How to replace Turn cleaner ON and rotate mode control dial to HARD FLOOR. Turn cleaner OFF and disconnect from electrical outlet. Place handle in upright position and turn cleaner over so bottom side is up. B 41 Pull up on agitator brush roll (B) to remove from brush roll cavity. A ® C 42 Holding agitator brush roll with one hand, slide belt (C) off the agitator. NOTE: Hold on to the belt with one hand. Do not allow the belt to fall back into the cavity on bottom of cleaner. 40 Remove the five screws as shown with a Phillips screwdriver. Lift off bottom plate (A). E D 43 Hold new agitator brush roll in one hand; the belt in the other. Slide the belt onto the agitator brush roll, positioning the belt in the belt guide (D) on the agitator brush roll. 44 Grasp agitator brush roll firmly and fit it into position by first sliding end opposite the belt into the rectangular slot (E) on side of the cleaner. Pull other side of agitator brush roll into place. Turn agitator brush roll making sure belt is not pinched between agitator brush roll and agitator brush roll shield. 45 Reposition bottom plate and five screws. Tighten screws securely. Agitator brush roll belt The agitator brush roll belt is designed to last the lifetime of the cleaner. It typically should not need replacement. If you feel the agitator brush roll belt needs to be checked or replaced, take your cleaner to an Authorized Hoover Sales and Service Center. Do not attempt to remove the agitator brush roll belt. (Cont'd) ¡ 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

®
13
(Cont’d)
What to buy
When purchasing a new agitator brush
roll, ask for
HOOVER part no.
48414140
.
How to replace
Turn cleaner ON and rotate mode con-
trol dial to HARD FLOOR. Turn cleaner
OFF and disconnect from electrical out-
let.
Place handle in upright position and
turn cleaner over so bottom side is up.
Remove the five screws as shown
with a Phillips screwdriver. Lift off
bottom plate (A).
40
Pull up on agitator brush roll (B)
to remove from brush roll cavity.
41
Holding agitator brush roll with
one hand, slide belt (C) off the
agitator.
NOTE:
Hold on to the belt with one
hand. Do not allow the belt to fall back
into the cavity on bottom of cleaner.
42
Hold new agitator brush roll in
one hand; the belt in the other.
Slide the belt onto the agitator brush roll,
positioning the belt in the belt guide (D)
on the agitator brush roll.
43
Grasp agitator brush roll firmly
and fit it into position by first slid-
ing end opposite the belt into the rectan-
gular slot (E) on side of the cleaner.
Pull other side of agitator brush roll into
place.
Turn agitator brush roll making sure belt
is not pinched between agitator brush
roll and agitator brush roll shield.
44
Reposition bottom plate and five
screws. Tighten screws securely.
45
Agitator brush roll belt
The agitator brush roll belt is designed to
last the lifetime of the cleaner. It typical-
ly should not need replacement.
If you
feel the agitator brush roll belt needs to
be checked or replaced, take your
cleaner to an Authorized Hoover
Sales and Service Center. Do not
attempt to r
emo
v
e the agitator brush
r
oll belt.
A
B
C
D
E