AH12H07D3B Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 20 amps, 230/208 Volt DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) ELECTRICAL WIRING • All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations. NOTE: Aluminum wiring may pose special problems - consult a qualified electrician. GRILLE OPTIONS • Stamped Aluminum Grille - RAG70 ELECTRICAL CONNECTION • 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations. • Power cord is permanently attached on all Hotpoint chassis. WALL CASE DIMENSIONS A C B RAB80 WALL SLEEVE Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A - 42", B - 13-3/4", C - 16" MAXIMUM CORD EXTENSION 30" 70" WALL OPENING DIMENSIONS Add 1/4" to A and C dimensions for all cut-outs. RAB80 16-1/4" Min. H x 42-1/4" Min. W AH12 ELECTRIC HEATER 230/208 VOLT LINE CORD CONNECTED UNITS Heater Watts 3,500 / 2,897 Heater BTU 10,900 / 8,900 Heater Amps 15.3 / 13.7 Min Circuit 20 Recommended protective Device 20 amp time-delay fuse or breaker AH12 HEAT PUMP Heat Pump Watts 485 / 465 Heat Pump BTU 6,200/6,000 COP 3.6 PRELIMINARY SPECIFICATIONS - SUBJECT TO CHANGE 31-5000805 Rev. 0 07-23 GEA

  • 1
  • 2

AH12H07D3B
Hotpoint
®
PTAC Heat Pump Unit with Electric Heat Backup 20 amps, 230/208 Volt
AH12 ELECTRIC HEATER
230/208 VOLT
LINE CORD CONNECTED UNITS
Heater Watts
3,500 / 2,897
Heater BTU
10,900 / 8,900
Heater Amps
15.3 / 13.7
Min Circuit
20
Recommended protective Device
20 amp time-delay fuse or breaker
PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE
31-5000805
Rev. 0
07-23
GEA
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
All wiring, including installation of receptacle, must be made in
accordance with local electrical codes and regulations.
NOTE:
Aluminum wiring may pose special problems – consult a qualified
electrician.
GRILLE OPTIONS
Stamped Aluminum Grille –
RAG70
ELECTRICAL CONNECTION
230/208 volt units must be plugged into a receptacle. Installation must
comply with local electrical codes and regulations.
Power cord is permanently attached on all Hotpoint chassis.
AH12 HEAT PUMP
Heat Pump Watts
485 / 465
Heat Pump BTU
6,200/6,000
COP
3.6
A
C
B
70"
30"
WALL CASE DIMENSIONS
RAB80 WALL SLEEVE
Heavy-gauge galvanized steel, with
insulation, for quick self-assembly.
A – 42”, B – 13-3/4”, C – 16”
MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS
Add 1/4” to A and C dimensions for all
cut-outs.
RAB80 16-1/4” Min. H x 42-1/4” Min. W