AH12H15D5B Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 30 amps, 230/208 Volt DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) ELECTRICAL WIRING • All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations. NOTE: Aluminum wiring may pose special problems - consult a qualified electrician. GRILLE OPTIONS • Stamped Aluminum Grille - RAG70 ELECTRICAL CONNECTION • 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations. • Power cord is permanently attached on all Hotpoint chassis. WALL CASE DIMENSIONS A C B RAB80 WALL SLEEVE Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A - 42", B - 13-3/4", C - 16" MAXIMUM CORD EXTENSION 30" 70" WALL OPENING DIMENSIONS Add 1/4" to A and C dimensions for all cut-outs. RAB80 16-1/4" Min. H x 42-1/4" Min. W AH12 ELECTRIC HEATER 230/208 VOLT LINE CORD CONNECTED UNITS Heater Watts 5,000 / 4,100 Heater BTU 15,000 / 12,200 Heater Amps 22.3 / 20.1 Min Circuit 30 Recommended protective Device 30 amp time-delay fuse or breaker AH12 HEAT PUMP Heat Pump Watts 1180 / 1120 Heat Pump BTU 13,400 / 13,100 COP 3.2 PRELIMINARY SPECIFICATIONS - SUBJECT TO CHANGE 31-5000817 Rev. 0 07-23 GEA

  • 1
  • 2

AH12H15D5B
Hotpoint
®
PTAC Heat Pump Unit with Electric Heat Backup 30 amps, 230/208 Volt
AH12 ELECTRIC HEATER
230/208 VOLT
LINE CORD CONNECTED UNITS
Heater Watts
5,000 / 4,100
Heater BTU
15,000 / 12,200
Heater Amps
22.3 / 20.1
Min Circuit
30
Recommended protective Device
30 amp time-delay fuse or breaker
PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE
31-5000817
Rev. 0
07-23
GEA
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
All wiring, including installation of receptacle, must be made in
accordance with local electrical codes and regulations.
NOTE:
Aluminum wiring may pose special problems – consult a qualified
electrician.
GRILLE OPTIONS
Stamped Aluminum Grille –
RAG70
ELECTRICAL CONNECTION
230/208 volt units must be plugged into a receptacle. Installation must
comply with local electrical codes and regulations.
Power cord is permanently attached on all Hotpoint chassis.
AH12 HEAT PUMP
Heat Pump Watts
1180 / 1120
Heat Pump BTU
13,400 / 13,100
COP
3.2
A
C
B
70"
30"
WALL CASE DIMENSIONS
RAB80 WALL SLEEVE
Heavy-gauge galvanized steel, with
insulation, for quick self-assembly.
A – 42”, B – 13-3/4”, C – 16”
MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS
Add 1/4” to A and C dimensions for all
cut-outs.
RAB80 16-1/4” Min. H x 42-1/4” Min. W