Hoveround Osprey Heavy Duty 4-Wheel Scooter User Manual - Page 20
Table 2: Scooter Controller Internal Diagnostics
View all Hoveround Osprey Heavy Duty 4-Wheel Scooter manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
For service assistance, please call your authorized ActiveCare dealer. Table 2: Scooter Controller Internal Diagnostics Flash code Possible Cause 1 The battery needs charging. 2 Battery voltage is too low. 3 Battery voltage too high 4 Current limit time out Solution The battery voltage has dropped below 23.3 volts in neutral. Recharge batteries. The battery has dropped past 16.5 volts and is not sufficient to allow safe driving. Check the battery condition and the connections. The battery has exceeded 32 volts. Check the battery condition and the connections. The motor current has reached too high a value. Check the condition of the motor and loom. Contact your Service Agent. 5 Park brake fault Check park brake conditions. 6 Speed control out of neutral 7 Speed control fault Return speed pod to neutral and rest system. Readjust the speed lever to neutral if necessary. Contact your Service Agent. Check speed pod wiring for open or short circuits. Check speed pot set-up. Contact your Service Agent. 8 Motor fault Contact your Service Agent. 9 Internal (controller) fault Contact your Service Agent. 19 Osprey 4410 Owner's Manual