Hunter 30180 Owner's Manual - Page 3

Cleaning And Filter Replacement, Operating Your Air Purifier

Page 3 highlights

Operating Your Air Purifier On/Speed Control: Rotate the Speed Control knob to set the desired speed. Unit off Low speed - Recommended for use when soft background noise is unwanted. Medium Speed - Typical usage setting. Soft background noise is not an issue. High speed - Use when quick, efficient results to a room's air quality are desired. The fan speed can be adjusted at any time. Press the Ionizer button to turn on the Ionizer function of your air purifier. The Ionizer Light will glow while the Ionizer is activated. counter, rotate the calendar ring to align the filter symbol ( ) with the month that you installed the filter. Since the filter is designed for 6 months use, the second indicator ( ) will serve as a reminder to check the filter every 6 months. If the HEPAtech filter ( ) is checked in April, then the filter would need to be checked again ( ) in October. Pre-filter Calendar: The outer knob of the filter calendar is the pre-filter counter. To use, align the pre-filter symbol ( ) on the ring with the month that you installed the pre-filter. The replacement symbol ( ) on the outer knob points to the month in which you should install a new pre-filter. The pre-filter is designed for 3 months of usage. Replacing the pre-filter ( ) in July means the filter would need to be replaced again ( ) in October. NOTE: DO NOT run the ionizer if tobacco smoke, air fresheners, dripless wax candles, or grease from cooking is present. Ionizer On/Speed Control Ionizer Indicator Power Indicator Figure 2 - Calendar Control Cleaning and filter Replacement 1. Clean the outside of the unit with a soft, damp cloth. Figure 3. Pre-Filter Calendar Filter Calendar Figure 1 - Purifier Controls Filter Change Calendar: The filter counter is designed to optimize the performance of the air purifier by reminding you when to change the HEPAtech Filter and pre-filter. It is located around the speed control dial. See Figure 2. 2. At least every 90 days, open the front grill, remove the carbon pre-filter, and replace it. This is necessary to maintain proper odorremoving and overall filtration performance. If necessary, it can be changed more often. Mark the new filter installation sticker included with the new carbon pre-filter and set the filter calendar dial. Be sure to remove any plastic wrapping that may be on the new filter before you place it into the Air Purifier. HEPAtech Filter Calendar: The HEPAtech Filter indicator is located in the center of the calendar ring. To set the HEPAtech Filter 3. Every 6 months you should remove the front grill and check the HEPAtech filter to see if it needs to be replaced. Compare the color ©2010 Hunter Fan Company 3 43063-01 20100615

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

3
©2010 Hunter Fan Company
43063-01
20100615
Figure 2 - Calendar Control
1. Clean the outside of the unit with a soft, damp
cloth. Figure 3.
2. At least every 90 days, open the front grill,
remove the carbon pre-filter, and replace it.
This is necessary to maintain proper odor-
removing and overall filtration performance.
If necessary, it can be changed more often.
Mark the new filter installation sticker
included with the new carbon pre-filter and
set the filter calendar dial. Be sure to remove
any plastic wrapping that may be on the new
filter before you place it into the Air Purifier.
3. Every 6 months you should remove the front
grill and check the HEPAtech filter to see if
it needs to be replaced. Compare the color
Filter Change Calendar:
The filter counter is
designed to optimize the performance of the
air purifier by reminding you when to change
the HEPAtech Filter and pre-filter. It is located
around the speed control dial. See Figure 2.
HEPAtech Filter Calendar:
The HEPAtech
Filter indicator is located in the center of the
calendar ring. To set the HEPAtech Filter
Pre-Filter Calendar
Filter Calendar
On/Speed
Control
Ionizer
Indicator
Ionizer
Figure 1 - Purifier Controls
Power
Indicator
CLEANING AND FILTER REPLACEMENT
On/Speed Control:
Rotate the Speed Control
knob to set the desired speed.
Unit off
Low speed - Recommended for
use when soft background noise
is unwanted.
Medium Speed - Typical usage setting.
Soft background noise is not an issue.
High speed - Use when quick, efficient
results to a room’s air quality are
desired.
The fan speed can be adjusted at any time.
Press the Ionizer button to turn on the Ionizer
function of your air purifier. The Ionizer Light will
glow while the Ionizer is activated.
NOTE: DO NOT run the ionizer if tobacco
smoke, air fresheners, dripless wax candles, or
grease from cooking is present.
OPERATING YOUR AIR PURIFIER
counter, rotate the calendar ring to align the filter
symbol (
) with the month that you installed the
filter. Since the filter is designed for 6 months
use, the second indicator (
) will serve as a
reminder to check the filter every 6 months. If
the HEPAtech filter (
) is checked in April, then
the filter would need to be checked again (
) in
October.
Pre-filter Calendar:
The outer knob of the
filter calendar is the pre-filter counter. To use,
align the pre-filter symbol (
) on the ring with
the month that you installed the pre-filter. The
replacement symbol (
) on the outer knob
points to the month in which you should install
a new pre-filter. The pre-filter is designed for 3
months of usage. Replacing the pre-filter (
) in
July means the filter would need to be replaced
again (
) in October.