Figure 4. Hunter R Y E O B G L C Carrier R Y or Y1 W2 E O G L or F C Coleman R Y W2 E B G L X Comfortmaker R Y W1 Jumper to W2 O Bryant, Payne R Y W2 E O G L or X C, X, X1 G L C, X, X1 Rheem Ruud R Y W2 E B G L X Trane, Weathertron R Y W X2 O G B York R Y W Jumper to W2 O G X B Lennox (1) R Y W1 E O G L C Lennox (2) V-VR M Y E R F X Thermostat Mounting Plate Wall Jumper Wall Jumper Conventional 4 Wire Heat / Cool RH RH RC Heat Power Y Y Cool Contactor G G Fan Relay W W Heat Contactor 5 Wire Heat / Cool RH RH Heat Power RC RC Cool Power Y Y Cool Contactor G G Fan Relay W W Heat Contactor Thermostat Mounting Plate Wall W2 W2 Y2 Y2 C C A A Thermostat Mounting Plate Heat Pump Single Stage Heat Pump R Y G L O B Aux/E Y2 C R Heat 24V Supply Y Compressor Contact G Fan Relay Cool Relay / Valve O Thermostat Mounting Plate Wall Jumper Wall Jumper Thermostat Mounting Plate Wall Jumper Wall Jumper 3 Wire Cool Only RH RC RC Cool Power Y Y Cool Contactor G G Fan Relay W W2 Y2 C A 2 Wire Heat Only RH RH RC Heat Power Y G W W Heat Contactor W2 Y2 C A 4 Wire with Common RH RH RC Heat Power Cool Power Y Y Cool Contactor G G Fan Relay W W Heat Contactor W2 Y2 C C A Common Jumper Wall Jumper Wall Jumper Wall Thermostat Mounting Plate Thermostat Mounting Plate Thermostat Mounting Plate 3 Wire Heat Only RH RH RC Heat Power Y G G Fan Relay W W Heat Contactor W2 Y2 C A 3 Wire Hot Water with Damper Valve RH RH RC Heat Power Y G W W Heat Contactor W2 Y2 C A A Damper Valve Conventional Multi-Stage RH RC RC Heat Power Y Y Cool Contactor G G Fan Relay W W Heat Contactor W2 W2 Second Stage Heat Y2 Y2 Second Stage Cool C A Single Stage Heat Pump W/Aux Heat Thermostat Mounting Plate R Y G L O B Aux/E Y2 C R Heat 24V Supply Y Compressor Contact G Fan Relay L System Monitor* O Cool Relay / Valve E Auxiliary Heat C Common* * The common wire "C" and system monitor wire "L" may or may not be present. Single Stage Heat Pump W/Heat Reversing Thermostat Mounting Plate R Y G L O B Aux/E Y2 C R Heat 24V Supply Y Compressor Contact G Fan Relay L System Monitor* B Heat Relay / Valve E Auxiliary Heat C Common* * The common wire "C" and system monitor wire "L" may or may not be present. Multi-Stage Heat Pump Thermostat Mounting Plate R Y G L O B Aux/E Y2 C R Heat 24V Supply Y Compressor Contact G Fan Relay L System Monitor* Cool Relay / Valve O E Auxiliary Heat Y2 Second-Stage Cool C Common* * The common wire "C" and system monitor wire "L" may or may not be present. Thermostat Mounting Plate Wall Jumper Wall Jumper

  • 1
  • 2

HEAT PUMP
Hunter
Carrier
Coleman
Comfortmaker
Bryant, Payne
Rheem Ruud
Trane,
Weathertron
York
Lennox (1)
Lennox (2)
R
R
R
R
R
R
R
R
R
V-VR
Y
Y or Y1
Y
Y
Y
Y
Y
Y
Y
M
E
W2
W2
W1
W2
W2
W
W
W1
Y
E
E
Jumper to W2
E
E
X2
Jumper to W2
E
E
O
O
O
O
O
O
O
R
B
B
B
G
G
G
G
G
G
G
G
G
F
L
L or F
L
L or X
L
L
X
L
C
C
X
C, X, X1
C, X, X1
X
B
B
C
X
Figure 4.
CONVENTIONAL
4 Wire Heat / Cool
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
RH
Y
G
W
Jumper
Heat Power
Cool Contactor
Fan Relay
Heat Contactor
3 Wire Cool Only
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
RC
Y
G
Jumper
Cool Power
Cool Contactor
Fan Relay
2 Wire Heat Only
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
RH
W
Jumper
Heat Power
Heat Contactor
4 Wire with Common
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
RH
Y
G
W
C
Jumper
Heat Power
Cool Power
Cool Contactor
Fan Relay
Heat Contactor
Common
5 Wire Heat / Cool
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
Heat Power
Cool Power
Cool Contactor
Fan Relay
Heat Contactor
RH
RC
Y
G
W
3 Wire Heat Only
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
RH
G
W
Jumper
Heat Power
Fan Relay
Heat Contactor
3 Wire Hot Water with Damper Valve
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
RH
W
A
Jumper
Heat Power
Heat Contactor
Damper Valve
Conventional Multi-Stage
°ermostat Mounting Plate
Wall
RH
RC
Y
G
W
W2
Y2
C
A
RC
Y
G
W
W2
Y2
Jumper
Heat Power
Cool Contactor
Fan Relay
Heat Contactor
Second Stage Heat
Second Stage Cool
Single Stage Heat Pump
°ermostat Mounting Plate
Wall
R
Y
G
L
O
B
Aux/E
Y2
C
R
Y
G
O
Jumper
Heat 24V Supply
Compressor Contact
Fan Relay
Cool Relay / Valve
°ermostat Mounting Plate
R
Y
G
L
O
B
Aux/E
Y2
C
Single Stage Heat Pump
W/Aux Heat
Wall
R
Y
G
O
E
C
Jumper
Heat 24V Supply
Compressor Contact
Fan Relay
System Monitor*
Cool Relay / Valve
Auxiliary Heat
Common*
* The common wire “C” and system monitor wire “L” may or
may not be present.
L
Single Stage Heat Pump W/Heat Reversing
°ermostat Mounting Plate
Wall
R
Y
G
L
O
B
Aux/E
Y2
C
R
Y
G
B
C
Jumper
L
* The common wire “C” and system monitor wire “L” may or
may not be present.
E
Heat 24V Supply
Compressor Contact
Fan Relay
System Monitor*
Heat Relay / Valve
Auxiliary Heat
Common*
Multi-Stage Heat Pump
°ermostat Mounting Plate
Wall
R
Y
G
L
O
B
Aux/E
Y2
C
R
Y
G
L
O
E
Y2
C
Jumper
* The common wire “C” and system monitor wire “L” may or
may not be present.
Heat 24V Supply
Compressor Contact
Fan Relay
System Monitor*
Cool Relay / Valve
Auxiliary Heat
Second-Stage Cool
Common*