Husqvarna 336LiC Operation Manual - Page 21
Troubleshooting schedule, Keypad, Battery, Battery charger
View all Husqvarna 336LiC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
MAINTENANCE Troubleshooting schedule Troubleshooting takes place from the keypad. Keypad Control panel Error LED flashes. The machine does not start Error LED is lit with red light. Possible faults Possible action The power trigger and the activate Release the power trigger and the button are pressed at the same time. machine is active. The trimmerhead is jammed. Overload. Remove the battery from the machine. Release the trimmer head from grass. Temperature deviation. Allow the machine to cool down. Dirt in battery connectors. Clean with compressed air or a soft brush. Service Contact your service agent. Troubleshooting the battery and/or the battery charger during charging. Battery LED display Green activate LED flashing. Error LED flashing Possible faults Low battery voltage. The battery is discharged. Temperature deviation. Error LED is lit Battery charger LED display Cell difference too much (1V). Possible faults Temperature deviation. Error LED flashing Over voltage. Error LED is lit Possible action Charge the battery. Charge the battery. Use the battery in surroundings where temperatures are between -10 °C and 40 °C. Contact your service agent. Possible action Use the battery charger only when the surrounding temperature is between 5 °C and 40 °C. Check that the mains voltage corresponds with that stated on the rating plate on the machine. Remove the battery from the battery charger. Contact your service agent. English - 21