Husqvarna 540i XP Owner Manual - Page 16

To use the correct chain oil, To connect the battery charger

Page 16 highlights

3. Do a check of the power trigger and the power trigger lockout (C) to make sure that they operate correctly and that they are not damaged. 4. Do a check of the keypad (D) to make sure that it operates correctly. 5. Make sure that there is no oil on the handles (E). 6. Do a check to make sure that all parts are correctly attached and not damaged or missing. 7. Do a check of the chain catcher (F) to make sure that it is attached correctly. 8. Do a check of the chain tension (G). 9. Charge the battery (H) and make sure that it is correctly attached to the product. 10. Make sure that the saw chain stops when you release the power trigger. C D EA B H F G To use the correct chain oil WARNING: Do not use waste oil, which can cause injury to you and the environment. Waste oil also causes damage to the oil pump, the guide bar and the saw chain. WARNING: The saw chain can break if the lubrication of the cutting equipment is not sufficient. Risk of serious injury or death to the operator. WARNING: Use the correct chain oil for this function to operate correctly. Speak to your servicing dealer when you select your chain oil. • Use Husqvarna chain oil for maximum saw chain life and to prevent negative effects on the environment. If Husqvarna chain oil is not available, we recommend you to use a standard chain oil. • Use a chain oil with good adherence to the saw chain. • Use a chain oil with correct viscosity range that agrees with the air temperature. CAUTION: In temperatures below 0°C/32°F some chain oils become too thick, which can cause damage to the oil pump components. • Use the recommended cutting equipment. Refer to Accessories on page 36. • Remove the cap to the chain oil tank. • Fill the chain oil tank with chain oil. • Attach the cap carefully. Note: To see where the chain oil tank is on you product, refer to Product overview on page 2. To connect the battery charger 1. Connect the battery charger to the voltage and frequency that is specified on the rating plate. 2. Put the plug in a grounded socket outlet. The LED on the battery charger flashes green one time. Note: The battery does not charge if the battery temperature is more than 50 °C/122 °F. If the temperature is more than 50 °C/122 °F, the battery charger makes the battery become cool before the battery charges. To connect the battery to the battery charger Note: Charge the battery if it is the first time that you use it. A new battery is only 30% charged. 1. Make sure that the battery is dry. 2. Put the battery in the battery charger. 16 1065 - 005 - 29.06.2020

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

3.
Do a check of the power trigger and the power
trigger lockout (C) to make sure that they operate
correctly and that they are not damaged.
4.
Do a check of the keypad (D) to make sure that it
operates correctly.
5.
Make sure that there is no oil on the handles (E).
6.
Do a check to make sure that all parts are correctly
attached and not damaged or missing.
7.
Do a check of the chain catcher (F) to make sure
that it is attached correctly.
8.
Do a check of the chain tension (G).
9.
Charge the battery (H) and make sure that it is
correctly attached to the product.
10. Make sure that the saw chain stops when you
release the power trigger.
A
B
H
F
G
C
D
E
To use the correct chain oil
WARNING:
Do not use waste oil,
which can cause injury to you and the
environment. Waste oil also causes
damage to the oil pump, the guide bar and
the saw chain.
WARNING:
The saw chain can break
if the lubrication of the cutting equipment is
not sufficient. Risk of serious injury or
death to the operator.
WARNING:
Use the correct chain oil
for this function to operate correctly. Speak
to your servicing dealer when you select
your chain oil.
Use Husqvarna chain oil for maximum saw chain
life and to prevent negative effects on the
environment. If Husqvarna chain oil is not
available, we recommend you to use a standard
chain oil.
Use a chain oil with good adherence to the saw
chain.
Use a chain oil with correct viscosity range that
agrees with the air temperature.
CAUTION:
In temperatures below
0°C/32°F some chain oils become too
thick, which can cause damage to the
oil pump components.
Use the recommended cutting equipment. Refer to
Accessories on page 36
.
Remove the cap to the chain oil tank.
Fill the chain oil tank with chain oil.
Attach the cap carefully.
Note:
To see where the chain oil tank is on you
product, refer to
Product overview on page 2
.
To connect the battery charger
1.
Connect the battery charger to the voltage and
frequency that is specified on the rating plate.
2.
Put the plug in a grounded socket outlet. The LED
on the battery charger flashes green one time.
Note:
The battery does not charge if the battery
temperature is more than 50 °C/122 °F. If the
temperature is more than 50 °C/122 °F, the battery
charger makes the battery become cool before the
battery charges.
To connect the battery to the battery
charger
Note:
Charge the battery if it is the first time that you
use it. A new battery is only 30% charged.
1.
Make sure that the battery is dry.
2.
Put the battery in the battery charger.
16