MAINTENANCE TRANSAXLE MAINTENANCE The transmission fan and cooling fins should be kept clean to assure proper cooling. Do not attempt to clean fan or transmission while engine is running or while the transmission is hot. To prevent possible damage to seals, do not use high pressure water or steam to clean transmission. • Inspect cooling fan to be sure fan blades are intact and clean. • Inspect cooling fins for dirt, grass clippings and other materials. To prevent damage to seals, do not use compressed air or high pressure sprayer to clean cooling fins. TRANSAXLE PUMP FLUID The transaxle was sealed at the factory and fluid maintenance is not required for the life of the transaxle. Should the transaxle ever leak or require servicing, contact your nearest authorized service center/department. ENGINE LUBRICATION Only use high quality detergent oil rated with API service classification SG-SL. Select the oil's SAE viscosity grade according to your expected operating temperature. SAE VISCOSITY GRADES 5W-30 SAE 30 F -20 0 30 32 40 60 80 100 C -30 -20 -10 0 10 20 30 40 TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE NOTE: Although multi-viscosity oils (5W30, 10W30 etc.) improve starting in cold weather, they will result in increased oil consumption when used above 32°F. Check your engine oil level more frequently to avoid possible engine damage from running low on oil. Change the oil after every 50 hours of operation or at least once a year if the tractor is not used for 50 hours in one year. Check the crankcase oil level before starting the engine and after each eight (8) hours of operation. Tighten oil fill cap/dipstick securely each time you check the oil level. CLOSED AND LOCKED POSITION YELLOW CAP OIL DRAIN VALVE 02463 DRAIN TUBE Fig. 16 • Remove the drain tube and replace the cap onto to the bottom fitting of the drain valve. • Refill engine with oil through oil fill dipstick tube. Pour slowly. Do not overfill. For approximate capacity see "PRODUCT SPECIFICATIONS" section of this manual. • Use gauge on oil fill cap/dipstick for checking level. Be sure dipstick cap is tightened securely for accurate reading. Keep oil at "FULL" line on dipstick. Tighten cap onto the tube securely when finished. ENGINE OIL FILTER Replace the engine oil filter every season or every other oil change if the tractor is used more than 100 hours in one year. AIR FILTER Your engine will not run properly using a dirty air filter. Service air cleaner more often under dusty conditions. CLEAN AIR SCREEN Air screen must be kept free of dirt and chaff to prevent engine damage from overheating. Clean with a wire brush or compressed air to remove dirt and stubborn dried gum fibers. ENGINE COOLING SYSTEM (See Fig. 17) Debris may clog the engine's air cooling system. Remove blower housing and clean the area shown to prevent overheating and engine damage. AIR SCREEN CLEAN OUT CHAFF AND DEBRIS TO CHANGE ENGINE OIL (See Fig. 16) Determine temperature range expected before oil change. All oil must meet API service classification SG-SL.. • Be sure tractor is on level surface. • Oil will drain more freely when warm. • Catch oil in a suitable container. • Remove oil fill cap/dipstick. Be careful not to allow dirt to enter the engine when changing oil. • Remove yellow cap from end of drain valve and install the drain tube onto the fitting. • Unlock drain valve by pushing inward and turning counterclockwise. • To open, pull out on the drain valve. • After oil has drained completely, close and lock the drain valve by pushing inward and turning clockwise until the pin is in the locked position as shown. 02744 Fig. 17 MUFFLER Inspect and replace corroded muffler and spark arrester (if equipped) as it could create a fire hazard and/or damage. SPARK PLUGS Replace spark plugs at the beginning of each mowing season or after every 100 hours of operation, whichever occurs first. Spark plug type and gap setting are shown in "PRODUCT SPECIFICATIONS" section of this manual. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

15
Fig. 16
TRANSAXLE MAINTENANCE
The transmission fan and cooling fins should be kept clean
to assure proper cooling.
Do not attempt to clean fan or transmission while engine
is running or while the transmission is hot. To prevent pos-
sible damage to seals, do not use high pressure water or
steam to clean transmission.
Inspect cooling fan to be sure fan blades are intact and
clean.
Inspect cooling fins for dirt, grass clippings and other
materials. To prevent damage to seals, do not use com-
pressed air or high pressure sprayer to clean cooling fins.
TRANSAXLE PUMP FLUID
The transaxle was sealed at the factory and fluid mainte-
nance is not required for the life of the transaxle.
Should
the transaxle ever leak or require servicing, contact your
nearest authorized service center/department.
MAINTENANCE
TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE
SAE VISCOSITY GRADES
-20
0
30
40
80
100
-30
-20
0
20
30
40
F
C
32
-10
10
60
5W-30
SAE 30
ENGINE
LUBRICATION
Only use high quality detergent oil rated with API service
classification SG-SL.
Select the oil’s SAE viscosity grade
according to your expected operating temperature.
NOTE:
Although multi-viscosity oils (5W30, 10W30 etc.)
improve starting in cold weather, they will result in increased
oil consumption when used above 32°F.
Check your engine
oil level more frequently to avoid possible engine damage
from running low on oil.
Change the oil after every 50 hours of operation or at least
once a year if the tractor is not used for 50 hours in one year.
Check the crankcase oil level before starting the engine
and after each eight (8) hours of operation.
Tighten oil fill
cap/dipstick securely each time you check the oil level.
TO CHANGE ENGINE OIL (See Fig. 16)
Determine temperature range expected before oil change.
All oil must meet API service classification
SG-SL..
Be sure tractor is on level surface.
Oil will drain more freely when warm.
Catch oil in a suitable container.
Remove oil fill cap/dipstick.
Be careful not to allow dirt
to enter the engine when changing oil.
Remove yellow cap from end of drain valve and install
the drain tube onto the fitting.
Unlock drain valve by pushing inward and turning
counterclockwise.
To open, pull out on the drain valve.
After oil has drained completely, close and lock the
drain valve by pushing inward and turning clockwise
until the pin is in the locked position as shown.
Remove the drain tube and replace the cap onto to the
bottom fitting of the drain valve.
Refill engine with oil through oil fill dipstick tube.
Pour
slowly.
Do not overfill.
For approximate capacity see
“PRODUCT SPECIFICATIONS” section of this manual.
Use gauge on oil fill cap/dipstick for checking level.
Be sure dipstick cap is tightened securely for accurate
reading.
Keep oil at “FULL” line on dipstick. Tighten
cap onto the tube securely when finished.
ENGINE OIL FILTER
Replace the engine oil filter every season or every other oil
change if the tractor is used more than 100 hours in one year.
02463
CLOSED
AND
LOCKED
POSITION
DRAIN
TUBE
OIL DRAIN VALVE
YELLOW CAP
AIR FILTER
Your engine will not run properly using a dirty air filter. Ser-
vice air cleaner more often under dusty conditions.
CLEAN AIR SCREEN
Air screen must be kept free of dirt and chaff to prevent
engine damage from overheating.
Clean with a wire brush or
compressed air to remove dirt and stubborn dried gum fibers.
ENGINE COOLING SYSTEM (See Fig. 17)
Debris may clog the engine's air cooling system. Remove
blower housing and clean the area shown to prevent over-
heating and engine damage.
CLEAN OUT CHAFF AND DEBRIS
02744
AIR SCREEN
Fig. 17
MUFFLER
Inspect and replace corroded muffler and spark arrester (if
equipped) as it could create a fire hazard and/or damage.
SPARK PLUGS
Replace spark plugs at the beginning of each mowing
season or after every 100 hours of operation, whichever
occurs first.
Spark plug type and gap setting are shown in