IBM 87302RU Hardware Maintenance Manual - Page 99

Symptom-to-FRU, index

Page 99 highlights

Chapter 6. Symptom-to-FRU index This index supports the BladeCenter T Type 8720 and 8730 systems. Eserver Notes: 1. Check the configuration before you replace a FRU. Configuration problems can cause false errors and symptoms. 2. For IBM devices not supported by this index, refer to the manual for that device. 3. A removed hot-swap module or drive must be replaced within one minute of removal. 4. A removed hot-swap blade must be replaced within 20 minutes of removal. The symptom-to-FRU index lists symptoms, errors, and the possible causes. The most likely cause is listed first. Use this symptom-to-FRU index to help you decide which FRUs to have available when servicing the system. The left-hand column of the tables in this index lists error codes or messages, and the right-hand column lists one or more suggested actions or FRUs to replace. Note: In tables with more than two columns, multiple columns are required to describe the error symptoms. Take the action or replace the FRU suggested first in the list of the right-hand column, then try the server again to see if the problem has been corrected before taking further action. Note: Try reseating a suspected component or reconnecting a cable before replacing the component. Error symptoms You can use the following information to find solutions to problems that have definite symptoms. Attention: If diagnostic error messages appear that are not listed in the following tables, make sure that your BladeCenter T unit has the latest level of firmware code installed. If you have just added a new option and your system is not working, complete the following procedure before using the troubleshooting charts: 1. Remove the option that you just added. 2. Run the diagnostic tests to determine if your system is running correctly. 3. Reinstall the new device. © Copyright IBM Corp. 2004 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Chapter
6.
Symptom-to-FRU
index
This
index
supports
the
Eserver
BladeCenter
T
Type
8720
and
8730
systems.
Notes:
1.
Check
the
configuration
before
you
replace
a
FRU.
Configuration
problems
can
cause
false
errors
and
symptoms.
2.
For
IBM
devices
not
supported
by
this
index,
refer
to
the
manual
for
that
device.
3.
A
removed
hot-swap
module
or
drive
must
be
replaced
within
one
minute
of
removal.
4.
A
removed
hot-swap
blade
must
be
replaced
within
20
minutes
of
removal.
The
symptom-to-FRU
index
lists
symptoms,
errors,
and
the
possible
causes.
The
most
likely
cause
is
listed
first.
Use
this
symptom-to-FRU
index
to
help
you
decide
which
FRUs
to
have
available
when
servicing
the
system.
The
left-hand
column
of
the
tables
in
this
index
lists
error
codes
or
messages,
and
the
right-hand
column
lists
one
or
more
suggested
actions
or
FRUs
to
replace.
Note:
In
tables
with
more
than
two
columns,
multiple
columns
are
required
to
describe
the
error
symptoms.
Take
the
action
or
replace
the
FRU
suggested
first
in
the
list
of
the
right-hand
column,
then
try
the
server
again
to
see
if
the
problem
has
been
corrected
before
taking
further
action.
Note:
Try
reseating
a
suspected
component
or
reconnecting
a
cable
before
replacing
the
component.
Error
symptoms
You
can
use
the
following
information
to
find
solutions
to
problems
that
have
definite
symptoms.
Attention:
If
diagnostic
error
messages
appear
that
are
not
listed
in
the
following
tables,
make
sure
that
your
BladeCenter
T
unit
has
the
latest
level
of
firmware
code
installed.
If
you
have
just
added
a
new
option
and
your
system
is
not
working,
complete
the
following
procedure
before
using
the
troubleshooting
charts:
1.
Remove
the
option
that
you
just
added.
2.
Run
the
diagnostic
tests
to
determine
if
your
system
is
running
correctly.
3.
Reinstall
the
new
device.
©
Copyright
IBM
Corp.
2004