Page 32 highlights
5 SET MODE s Quick set mode items- (continued) • BK-IN This item selects break-in type for CW operation. There are three selectable values: oF : No break-in operation available (default). SE : Semi break-in operation available. FL : Full break-in operation available. • BK-IN delay This item adjusts break-in delay time for CW semi break-in operation. The delay time is selectable from 2.0 to 13 (dots). The default is 7. • Key speed This item adjusts the CW key speed. The key speed can be selected from 6 to 60* wpm. The default is 20 wpm. *40, 44, 47, 50, 52, 54, 56, 57, 59 cannot be selected. • Key ratio This item sets the CW key ratio (or weight). The ratio can be selected from 2.8 to 4.5. The default is 30 (3.0). • RTTY mark tone This item selects RTTY tone. There are 3 selectable values: 1275, 1615 and 2125 Hz. The default is 2125 Hz. • RTTY shift This item adjusts RTTY shift. There are 4 selectable values: 170, 200, 425 and 850. The default is 170 Hz. • Dimmer This item selects LCD back light brightness. There are 3 selectable values: Off, Low and High. The default is HI (High). • Tuning step This item selects tuning step for the channel selector's tuning. The default is 1 k (1 kHz). 30