Icom IC-F6123D Instruction Manual - Page 17
Emergency transmission
View all Icom IC-F6123D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
BASIC OPERATION 2 ■ Emergency transmission When [Emergency] is held down for the specified time pe- D NOTES 2 riod*, the emergency signal is transmitted on the specified Depending on the preprogramming, the following functions emergency channel once or repeatedly. are automatically activated. Ask your dealer for details. When no emergency channel is specified, the call is transmit- ted on the operating channel. • Auto TX function After the emergency call transmission, audio from the micro- The repeat emergency signal is automatically transmitted phone is automatically transmitted for a specified time pe- until you turn OFF the power. riod.* Depending on the preprogramming, receiving a matching • The HM-148G or HM-152 hand microphone is required. 5-tone code cancels the transmission. • Auto RX function If you want to cancel the Emergency function, hold down After the emergency call transmission, the transceiver stands [Emergency] for the pre-programmed time period again be- by in the audible mode for the specified time period.* fore transmitting the call. * Depending on the preprogramming. Ask your dealer for de- If your transceiver is programmed for Silent operation, you tails. can transmit emergency calls without the beep sounding and the LCD indication change. IMPORTANT: It is recommended to set an emergency channel individually to provide the certain emergency call operation. 13