Icom IC-FR6000 Instruction Manual - Page 10

Front panel connection, ACC CONNECTOR, RX ANT], EXTERNAL SPEAKER

Page 10 highlights

2 INSTALLATION AND CONNECTIONS n Front panel connection P0 P1 P2 P3 P4 HM-152 HAND MICROPHONE (optional) SM-26 DESKTOP MICROPHONE (optional) MICROPHONE CONNECTOR (Front panel view) q +8 V DC output (Max. 15 mA) w Output port for PC programming q i e NC r M PTT (Input port for TX control) t Microphone ground y Microphone input u Ground i Input port for PC programming CAUTION: DO NOT short pin 1 to ground as this can damage the internal 8 V regulator. DC voltage is applied to pin 1 for microphone operation. Only Icom microphones are recommended. n Rear panel connection EXTERNAL SPEAKER 4 ø external speaker. [RX ANT] (p. 4) ACC CONNECTOR (p. 3) Used for external equipment control. [TX ANT] (p. 4) 125 V 1 A fuses Red Supplied DC power cable (CAB-1149)*1 To a 13.6 V DC power source Black R WARNING! NEVER remove the fuse-holder from the DC power receptacle or cable. R When you disconnect the DC power cable, take care to not crack of your fingernail. w q Push 32 V 20 A fuses AC outlet DC power supply 13.6 V *2 ; at least 20 A Red Black +_ AC cable Supplied DC power cable (OPC-1784) Red Black *1 This connection may not be required, depending on the repeater version. The repeater rear panel may be different, depending on the repeater version. *2 13.2 V for the European versions. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

n
Front panel connection
P
0
P
1
P
2
P
3
P
4
SM-26 DESKTOP
MICROPHONE
(optional)
MICROPHONE CONNECTOR
(Front panel view)
HM-152 HAND
MICROPHONE
(optional)
q
i
CAUTION: DO NOT
short pin 1 to ground as this can
damage the internal 8 V regulator. DC voltage is applied
to pin 1 for microphone operation. Only Icom micro-
phones are recommended.
q
+8 V DC output (Max. 15 mA)
w
Output port for PC programming
e
NC
r
M PTT (Input port for TX control)
t
Microphone ground
y
Microphone input
u
Ground
i
Input port for PC programming
n
Rear panel connection
ACC CONNECTOR
(p. 3)
Used for external equipment
control.
[RX ANT]
(p. 4)
[TX ANT]
(p. 4)
EXTERNAL SPEAKER
R
WARNING!
NEVER
remove the
fuse-holder from the
DC power recepta-
cle or cable.
4
ΓΈ
external speaker.
Black
Red
Black
Red
32 V 20 A
fuses
DC power supply
AC outlet
AC cable
Supplied
DC power cable (OPC-1784)
13.6 V
*
2
; at least 20 A
Black
_
Red
+
q
Push
w
R
When you disconnect the
DC power cable, take care to
not crack of your fingernail.
Supplied
DC power
cable (CAB-1149)*
1
125 V 1 A fuses
To a 13.6 V
DC power source
*
1
This connection may not be required, depending on the repeater version.
The repeater rear panel may be different, depending on the repeater version.
*
2
13.2 V for the European versions.
5
2
INSTALLATION AND CONNECTIONS