NS-AC06PWH1/NS-AC07PWH1/NS-AC08PWH1 Storing your air conditioner CAUTION: Store your air conditioner in a cool, dark place. Exposure to direct sunshine or extreme heat can shorten the lifespan of your air conditioner. 1 Run the fan for 12 hours, then empty the drain tray. See Emptying the drain tray on page 26. 2 Run your air conditioner in FAN mode for 12 hours in a warm room to dry it and prevent mold. 3 Turn off and unplug your air conditioner. 4 Clean and reinstall the air filter. See Cleaning the air filter on page 26. 5 Remove the batteries from the remote control. Troubleshooting PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION P1 Error Code. The water collection tray is full. Turn off your air conditioner, drain the water from the tray, then restart your air conditioner. See Emptying the drain tray on My air conditioner doesn't page 26. turn off when I press the ON/OFF button or Your air conditioner is set to the Cool mode, and the room Reset the temperature. See Setting the operating temperature on page 23. temperature is lower than the set temperature. The temperature setting is too Set the temperature to a lower setting. See Setting the high. operating temperature on page 23. The air filter is blocked with dust Turn off your air conditioner, then clean the filter. See or animal hair. Cleaning the air filter on page 26. The windows or doors in the room are open. Close the windows or doors. My air conditioner doesn't cool well There are heat sources in the room. The room area is too large. Remove the heat sources. The recommended room areas are: • NS-AC06PWH1: 150-250 sq. ft. • NS-AC07PWH1: 250-300 sq. ft. • NS-AC08PWH1: 300-350 sq. ft. The exhaust hose isn't connected Turn off your air conditioner, disconnect the hose, or is blocked. check for blockage, then reconnect the hose. See STEP 1: Connect the exhaust hose to your air conditioner on page 17. The refrigerant level is low. Contact a qualified service technician to check your air conditioner and add refrigerant. My air conditioner is noisy and vibrates The floor is not level. Place your air conditioner on a flat, level surface. The air filter is blocked with dust Turn off your air conditioner, then clean the filter. See or animal hair. Cleaning the air filter on page 26. My air conditioner makes a This sound is caused by the flow This is normal. gurgling sound of refrigerant inside your air conditioner. www.insigniaproducts.com 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

www.insigniaproducts.com
27
NS-AC06PWH1/NS-AC07PWH1/NS-AC08PWH1
Storing your air conditioner
1
Run the fan for 12 hours, then empty the drain tray. See Emptying the drain tray
on page 26
.
2
Run your air conditioner in FAN mode for 12 hours in a warm room to dry it and prevent mold.
3
Turn off and unplug your air conditioner.
4
Clean and reinstall the air filter. See Cleaning the air filter
on page 26
.
5
Remove the batteries from the remote control.
Troubleshooting
CAUTION:
Store your air conditioner in a cool, dark place. Exposure to direct sunshine or extreme heat can shorten the lifespan of your
air conditioner.
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTION
My air conditioner doesn’t
turn off when I press the
or
ON/OFF
button
P1 Error Code.
The water collection tray is full. Turn off your air
conditioner, drain the water from the tray, then restart
your air conditioner. See Emptying the drain tray
on
page 26
.
Your air conditioner is set to the
Cool
mode, and the room
temperature is lower than the set
temperature.
Reset the temperature. See Setting the operating
temperature
on page
23
.
My air conditioner doesn’t
cool well
The temperature setting is too
high.
Set the temperature to a lower setting. See Setting the
operating temperature
on page 23
.
The air filter is blocked with dust
or animal hair.
Turn off your air conditioner, then clean the filter. See
Cleaning the air filter
on page 26
.
The windows or doors in the
room are open.
Close the windows or doors.
There are heat sources in the
room.
Remove the heat sources.
The room area is too large.
The recommended room areas are:
NS-AC06PWH1: 150-250 sq. ft.
NS-AC07PWH1: 250-300 sq. ft.
NS-AC08PWH1: 300-350 sq. ft.
The exhaust hose isn’t connected
or is blocked.
Turn off your air conditioner, disconnect the hose,
check for blockage, then reconnect the hose. See
STEP 1: Connect the exhaust hose to your air
conditioner
on page 17
.
The refrigerant level is low.
Contact a qualified service technician to check your air
conditioner and add refrigerant.
My air conditioner is noisy
and vibrates
The floor is not level.
Place your air conditioner on a flat, level surface.
The air filter is blocked with dust
or animal hair.
Turn off your air conditioner, then clean the filter. See
Cleaning the air filter
on page 26
.
My air conditioner makes a
gurgling sound
This sound is caused by the flow
of refrigerant inside your air
conditioner.
This is normal.