Insignia NS-AC12PWH9 Quick Setup Guide - Page 1
Insignia NS-AC12PWH9 Manual
View all Insignia NS-AC12PWH9 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
QUICK SETUP GUIDE Portable Air Conditioner NS-AC10PWH9 / NS-AC10PWH9-C NS-AC12PWH9 / NS-AC12PWH9-C PACKAGE CONTENTS • Portable air conditioner • Remote control with batteries • Exhaust nozzle • Assembly hardware • Exhaust hose • Hose adapter • Window seal plate assembly • Quick Setup Guide FIND YOUR USER GUIDE ONLINE! 1 Go to www.insigniaproducts.com. 2 Use the search bar to find NS-AC10PWH9, NS-AC10PWH9-C, NS-AC12PWH9, or NS-AC12PWH9-C. 3 Select Support & Downloads. 4 Next to User Guide, select the language you want. IMPORTANT The air conditioner unit must always be stored and transported upright, otherwise you may cause irreparable damage to the compressor. In case of doubt, we suggest that you wait for at least 24 hours before you start the air-conditioning unit. SAFETY INFORMATION 1 Read and keep these instructions. 2 Heed all warnings. 3 Follow all instructions. 4 Do not use this machine near water. 5 Clean only with a damp cloth. 6 Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 7 Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 8 Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 9 Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the machine. 10 Do not attempt to modify or extend the power cord of this machine. 11 Unplug this machine during lightning storms or when it will not be used for long periods of time. 12 Make sure that the available AC power matches the voltage requirements of this machine. 13 Do not handle the plug with wet hands. This could result in an electric shock. 14 Unplug the power cord by holding the plug, never by pulling the cord. 15 Do not turn the machine on or off by plugging or unplugging the power cord. 16 Turn off the machine before unplugging it. Before using your new product, please read these instructions to prevent any damage. 17 Refer all servicing to qualified service personnel. Servicing is required when the machine has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the machine, the machine has been exposed to rain or moisture, does not operate normally, or has been dropped. 18 To reduce the risk of fire or electric shock, do not expose this machine to rain, moisture, dripping, or splashing, and no objects filled with liquids should be placed on top of it. 19 Batteries should not be exposed to excessive heat such as sunshine, fire, or the like. CAUTION: Danger of explosion if batteries are incorrectly replaced. Replace only with the same or equivalent type. Additional precautions • This machine is intended for household use. Do not use for any other purpose. • Use this machine indoors in a dry location only. Do not use it outdoors. • Do not place heavy objects on the machine, as this could damage it. • Wipe the machine with a soft cloth to clean it. Do not use wax, thinner, or irritating detergents. • Do not allow children or pets to drink the water discharged by the machine. • Do not disassemble or attempt to repair the machine yourself. • Do not plug this machine into an outlet with several other high electrical usage appliances. • Keep the machine away from heat sources and avoid direct sunlight. • If the machine is making a loud noise or producing an odor or smoke, switch off it, disconnect the plug, and immediately try to determine the cause. • Do not place heavy objects on the power cord to avoid it being crushed and causing an electric shock. • Do not put your fingers or hard objects into the outlet air guide bars. • Turn the machine off and unplug it if there is water inside it, then contact qualified service personnel for servicing. • Turn the machine off and unplug it before cleaning, moving, or servicing it. • To avoid injury, do not allow children or other individuals with special needs to touch or operate the machine. The machine should only be used with adult supervision. • Place the air conditioner on a flat surface and upright to ensure the normal operation of the compressor. • Do not use the machine near gasoline or other flammable liquids. • Do not use aerosol sprays or other solvents near the machine. This may cause plastic deformation or possibly damage the electrical components of the machine. • Avoid restarting the air conditioning unit unless three minutes have passed since being turned off, or the compressor may get damaged. WARNING: ELECTRIC SHOCK HAZARD Failure to follow these instructions can result in electric shock, fire, or death. • This unit must be properly grounded. • Do not, under any circumstances, cut or remove the grounding plug. • If you do not have a properly grounded AC outlet, or if there is any doubt that the outlet is not properly grounded, a qualified electrician should check the outlet and circuit and, if necessary, install a properly grounded outlet. • This air conditioner must be plugged into a grounded 115V, 60 Hz AC outlet, protected by a 15 amp time-delay fuse or circuit breaker. • This air conditioner must be installed in accordance with national wiring codes. • Do not alter or modify the plug or cord of this air conditioner. If the power cord becomes worn or damaged, the cord should only be replaced by a qualified service technician using genuine replacement parts. • Do not use an extension cord. ELECTRICAL SAFETY Integrated circuit breaker For additional safety, the power cord on this air conditioner features an integrated circuit breaker. You can test and reset the circuit breaker using the buttons provided on the plug case. Consult a qualified electrician or service person if the grounding instructions are not completely understood, or if doubt exists as to whether the air conditioner is properly grounded. RESET button TEST button The circuit breaker should be tested periodically by pressing the TEST button, then pressing the RESET button. If the TEST button does not cause the circuit breaker to trip, or if the RESET button does not stay engaged, unplug the air conditioner immediately and contact an Insignia technician. Preferred grounding method Make sure that a proper ground exists before use. Temporary grounding Due to potential safety hazards, we strongly discourage the use of an adapter plug. If an adapter plug must be used for a temporary connection, use only a UL-listed adapter. The minimum capacity for 10,000 BTU is 120V, 60Hz, 13A, and 1560W, and for 12,000 BTU is 120V, 60Hz, 15A, and 1800W. Make sure that the large slot of the adapter is aligned with the large slot in the outlet. To prevent damage to the adapter's ground terminal, hold the adapter in place while plugging or unplugging the air conditioner. Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring. Frequent connection and disconnection can damage the ground terminal on the adapter. Never use a broken or damaged adapter. Make sure that a proper ground exists before use. FEATURES • 6,500 BTU DOE/10,000 BTU ASHRAE (NS-AC10PWH9/NS-AC10PWH9-C) or 7,500 BTU DOE/12,000 BTU ASHRAE (NS-AC12PWH9/NS-AC12PWH9-C) rated cooling capacity • 3-in-1 design (air conditioner, dehumidifier, and fan) Front Back Control panel and display • Digital controls with LED display • Multiple fan speeds with auto-control • Programmable timer and remote control • Auto On/Off Handles (2) Adjustable louvered air discharge Exhaust outlet Air inlet Swiveling casters Drain outlet Filter and filter case Control panel TIMER button Remote control receiver MODE button / (TEMP/TIMER) buttons SPEED button Power cord SWING button Power button Timer indicator Mode indicators LED display Temperature/timer display Fan speed indicators Power indicator