Insignia NS-AC8PWH9 Quick Setup Guide - Page 2

Using Your Air Conditioner, Troubleshooting, Specifications, Contact Insignia, Installing Your Air - user guide

Page 2 highlights

Remote control # ITEM 1 Speed settings 2 Timer button 3 (up) and  (down) buttons 4 Cool button 5 Dry button 6 Fan button DESCRIPTION Press to raise or lower the fan speed. Press to set the air conditioner to turn on or off automatically. In cool mode, press to raise () or lower () the temperature setting. In timing mode, press to turn the timer on () or off (). Press to set the air conditioner to Cooling mode. Press to set the air conditioner to Dry mode (runs both the fan and dehumidifier). Press to turn on the fan only (no cooling). 7 °C /°F button 8 Power button Press to switch between Celsius and Fahrenheit. Press to turn the air conditioner on or off. SETTING UP YOUR PORTABLE AIR CONDITIONER Before using your portable air conditioner • Remove and store (optional) packing materials for reuse. • Remove any shipping tape before using the air conditioner. • Remove tape residue with liquid dish soap and a damp cloth. Do not use sharp tools, alcohol, thinners, or abrasive cleaners to remove adhesive, which could damage the finish. Placing your air conditioner • Place the unit on a flat, dry area near a window, so you can use the hose and diffuser to connect the air conditioner to the window installation kit in order to vent the exhaust air outside. • To maintain good air circulation and optimum machine performance, leave a 20 in. (50 cm) space around it. 20 in. (50 cm) 20 in. (50 cm) INSTALLING YOUR AIR CONDITIONER 1 Screw the exhaust hose to the exhaust outlet on the back of your air conditioner, then screw the hose adapter to the other end of the hose. 2 Measure the window size. OR 3 Install the window sealing plate in the window opening, adjusting the length to fit the window opening and securing it with screw A (provided). Note: Note: The window sealing kit works with sliding windows. Screw A 4 Insert the hose adapter into the vent panel (A), then slide the adapter until it clicks into place (B). Small gap Insert Slide (Optional): Secure the venting hose to the vent adapter using the included screw. See your User Guide for details. Note: For optimum performance, make sure the venting hose is not twisted and is free of kinks. For better efficiency, shorten the hose by squeezing its sections together. Caution: The exhaust duct is designed especially for this air conditioner. Replacing or lengthening the duct could result in damage to your unit. 5 (Optional) Install the security bracket with the type C screw. Type C screw Security bracket Running your air conditioner in DRY mode If you want to continuously drain the water from your air conditioner and never have to manually drain the collection tank, see your online User Guide. USING YOUR AIR CONDITIONER Inserting the batteries in the remote control • Insert two AAA batteries (provided) into the remote control. Make sure that you orient the batteries correctly (+ and -) when you install them. Turning your air conditioner on and selecting the mode Note: See your User Guide for more information about the types of sounds that your air conditioner may make. 1 Press Power ( ) to turn your air conditioner on. 2 On your air conditioner, press Mode repeatedly to select Cool, Dry, or Fan mode. • Cool mode: The air conditioner cools your room. • Dry mode: The fan and dehumidifier run to remove humidity from the air. Dry mode does not cool the room. • Fan mode: The fan circulates air, but does not cool it. 3 In Cool or Fan mode, press SPEED (AC unit) or High/Low (remote control) to adjust the fan's speed. Note: In dry mode, the fan speed cannot be changed. Switching between Celsius and Fahrenheit • Press °C/°F on the remote control. Setting a timer Set your air conditioner to turn off or turn on after a delay of up to 24 hours. • Automatic off: Press  or  while the air conditioner is running. • Automatic on: Press  or  while the air conditioner is off. The timer indicator lights up when the timer is set. See your online User Guide for more information on using your air conditioner. Understanding LED display messages ITEM DESCRIPTION FL The internal water tank is full and needs to be emptied. See your online User Guide for more information. E1 Coil temperature sensor error. Turn off your air conditioner and call a professional maintenance technician or service center. E2 Indoor temperature sensor error. Turn off your air conditioner and call a professional maintenance technician or service center. Anti-freezing protection. The air conditioner coil E4 temperature is too low and the unit has turned off automatically. The unit resets itself when the temperature reaches 46.4°F (8°C). TROUBLESHOOTING For troubleshooting information see your online User Guide. SPECIFICATIONS For specifications see your online User Guide. ONE-YEAR LIMITED WARRANTY Visit www.insigniaproducts.com for details or see your online User Guide. CONTACT INSIGNIA: For customer service, call 1-877-467-4289 (U.S. and Canada) or 01-800-926-3000 (Mexico) www.insigniaproducts.com INSIGNIA is a trademark of Best Buy and its affiliated companies Distributed by Best Buy Purchasing, LLC 7601 Penn Ave South, Richfield, MN 55423 U.S.A. ©2019 Best Buy. All rights reserved. V3 ENGLISH 19-0717

  • 1
  • 2

4
Insert the hose adapter into the vent panel (A), then slide the
adapter until it clicks into place (B).
(Optional)
: Secure the venting hose to the vent adapter using the
included screw. See your
User Guide
for details.
Note
: For optimum performance, make sure the venting hose is not
twisted and is free of kinks. For better efficiency, shorten the hose by
squeezing its sections together.
Caution
: The exhaust duct is designed especially for this air
conditioner. Replacing or lengthening the duct could result in
damage to your unit.
5
(Optional) Install the security bracket with the type C screw.
Running your air conditioner in DRY mode
If you want to continuously drain the water from your air
conditioner and never have to manually drain the collection
tank, see your online
User Guide
.
V3 ENGLISH 19-0717
USING YOUR AIR CONDITIONER
Inserting the batteries in the remote control
Insert two AAA batteries (provided) into the remote control.
Turning your air conditioner on and selecting the mode
Note:
See your
User Guide
for more information about the types of
sounds that your air conditioner may make.
1
Press
Power
(
) to turn your air conditioner on.
2
On your air conditioner, press
Mode
repeatedly to select
Cool, Dry, or Fan mode.
Cool mode
: The air conditioner cools your room.
Dry mode
: The fan and dehumidifier run to remove
humidity from the air. Dry mode does not cool the room.
Fan mode
: The fan circulates air, but does not cool it.
3
In Cool or Fan mode, press
SPEED
(AC unit) or
High/Low
(remote control) to adjust the fan's speed.
Note:
In dry mode, the fan speed cannot be changed.
Switching between Celsius and Fahrenheit
Press
°C/°F
on the remote control.
Setting a timer
Set your air conditioner to turn off or turn on after a delay of up
to 24 hours.
Automatic off
: Press
or
while the air conditioner is
running.
Automatic on
: Press
or
while the air conditioner is off.
The timer indicator lights up when the timer is set.
See your online
User Guide
for more information on using your
air conditioner.
Understanding LED display messages
TROUBLESHOOTING
For troubleshooting information see your online
User Guide
.
SPECIFICATIONS
For specifications see your online
User Guide
.
ONE±YEAR LIMITED WARRANTY
Visit www.insigniaproducts.com for details or see your online
User Guide
.
CONTACT INSIGNIA:
For customer service, call 1-877-467-4289 (U.S. and Canada)
or 01-800-926-3000 (Mexico)
www.insigniaproducts.com
INSIGNIA is a trademark of Best Buy and its affiliated companies
Distributed by Best Buy Purchasing, LLC
7601 Penn Ave South, Richfield, MN 55423 U.S.A.
©2019 Best Buy. All rights reserved.
INSTALLING YOUR AIR CONDITIONER
1
Screw the exhaust hose to the exhaust outlet on the back of
your air conditioner, then screw the hose adapter to the
other end of the hose.
2
Measure the window size.
3
Install the window sealing plate in the window opening,
adjusting the length to fit the window opening and
securing it with screw A (provided).
Note:
Note: The window sealing kit works with sliding windows.
Remote control
SETTING UP YOUR PORTABLE AIR CONDITIONER
Before using your portable air conditioner
Remove and store (optional) packing materials for reuse.
Remove any shipping tape before using the air conditioner.
Remove tape residue with liquid dish soap and a damp cloth.
Do not use sharp tools, alcohol, thinners, or abrasive cleaners to
remove adhesive, which could damage the finish.
Placing your air conditioner
Place the unit on a flat, dry area near a window, so you can use
the hose and diffuser to connect the air conditioner to the
window installation kit in order to vent the exhaust air outside.
To maintain good air circulation and optimum machine
performance, leave a 20 in. (50 cm) space around it.
#
ITEM
1
Speed settings
2
Timer
button
3
(up) and
(down) buttons
4
Cool
button
5
Dry
button
6
Fan
button
7
°C /°F
button
8
Power
button
DESCRIPTION
Press to raise or lower the fan speed.
Press to set the air conditioner to turn on or off
automatically.
In cool mode, press to raise (
) or lower (
)
the temperature setting.
In timing mode, press to turn the timer on (
)
or off (
).
Press to set the air conditioner to Cooling
mode.
Press to set the air conditioner to Dry mode
(runs both the fan and dehumidifier).
Press to turn on the fan only (no cooling).
Press to switch between Celsius and Fahrenheit.
Press to turn the air conditioner on or off.
20 in. (50 cm)
20 in. (50 cm)
Type C screw
Security bracket
Make sure that you orient the
batteries correctly (+ and –)
when you install them.
ITEM
FL
E1
E2
E4
DESCRIPTION
The internal water tank is full and needs to be
emptied. See your online
User Guide
for more
information.
Coil temperature sensor error. Turn off your air
conditioner and call a professional maintenance
technician or service center.
Indoor temperature sensor error. Turn off your air
conditioner and call a professional maintenance
technician or service center.
Anti-freezing protection. The air conditioner coil
temperature is too low and the unit has turned off
automatically. The unit resets itself when the
temperature reaches 46.4°F (8°C).
Insert
Slide
Small gap
Screw A
OR