Intel H2000 Technical Product Specification - Page 101

Appendix A: Integration and Usage Tips

Page 101 highlights

Appendix A: Integration and Usage Tips Intel® Server System H2000JF Family TPS Appendix A: Integration and Usage Tips Before attempting to integrate and configure your system, you should reference this section, which provides a list of useful information.  After the system is integrated with processors, memory, and peripheral devices, the FRUSDR utility must be run to load the proper Sensor Data Record data to the integrated Server Management subsystem. Failure to run this utility may prevent Server Management from accurately monitoring system health and may affect system performance. The FRUSDR utility for this server system can either be run from the Intel® Deployment CDROM that came with your system, or can be downloaded from the Intel® website referenced at the bottom of this page.  To ensure the highest system reliability, make sure the latest system software is loaded on the server before deploying the system onto a live networking environment. This includes system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. The system software can be updated using the Intel® Deployment CDROM that came with your system or can be downloaded from the Intel® website referenced at the bottom of this page.  System fans are not hot-swappable.  Only supported memory validated by Intel® should be used in this server system. A list of supported memory can be found in the Intel® Server Board S2600JF Tested Memory List which can be downloaded from the Intel® website referenced at the bottom of this page.  This system supports the Intel® Xeon® processor E5-2600 sequence. You cannot use Intel® Xeon® processors not referenced on the supported processor list in this server system.  You must use the CPU/memory air duct to maintain system thermals.  To maintain system thermals, you must populate all hard drive bays with either a hard drive or drive blank.  You must remove AC power from the system prior to opening the chassis for service You can download the latest system documentation, drivers, and system software from the Intel® Support website at http://www.intel.com/p/en_US/support/highlights/server/ss-h2000jf. Revision 1.6 89 Intel order number: G39462-007

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

Appendix A: Integration and Usage Tips
Intel
®
Server System H2000JF Family TPS
Revision 1.6
89
Intel order number: G39462-007
Appendix A: Integration and Usage Tips
Before attempting to integrate and configure your system, you should reference this section,
which provides a list of useful information.
After the system is integrated with processors, memory, and peripheral devices, the
FRUSDR utility
must
be run to load the proper Sensor Data Record data to the
integrated Server Management subsystem. Failure to run this utility may prevent Server
Management from accurately monitoring system health and may affect system
performance. The FRUSDR utility for this server system can either be run from the Intel
®
Deployment CDROM that came with your system, or can be downloaded from the Intel
®
website referenced at the bottom of this page.
To ensure the highest system reliability, make sure the latest system software is loaded
on the server before deploying the system onto a live networking environment. This
includes system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. The
system software can be updated using the Intel
®
Deployment CDROM that came with
your system or can be downloaded from the Intel
®
website referenced at the bottom of
this page.
System fans are not hot-swappable.
Only supported memory validated by Intel
®
should be used in this server system. A list of
supported memory can be found in the
Intel
®
Server Board S2600JF Tested Memory
List
which can be downloaded from the Intel
®
website referenced at the bottom of this page.
This system supports the Intel
®
Xeon
®
processor E5-2600 sequence. You cannot use
Intel
®
Xeon
®
processors not referenced on the supported processor list in this server
system.
You must use the CPU/memory air duct to maintain system thermals.
To maintain system thermals, you must populate all hard drive bays with either a hard
drive or drive blank.
You must remove AC power from the system prior to opening the chassis for service
You can download the latest system documentation, drivers, and system software from the
Intel
®
Support website at
.